Power supply
12 V DC or 24 V DC
Min. voltage
10 V DC
Max. voltage
32 V DC
Residual ripple
max. 10 % maximum at 100 Hz
Current consumption
max. 1 A
Admissible voltage drop
at max. power consumption
max. 10 % at control unit
Fuse 6
A
Storage temperature
-40°C to +85°C
Operating temperature
-40°C to +80°C
Air humidity
up to 98 % at 55 °C
Vibration
max. 2 mm at 10..20 Hz
max. 0.24 mm at 21..63 Hz
max. 9 g at 64..2000 Hz
Shock
50 g, 11 ms, half sine
Protection grade
IP 00
Isolation resistance
> 1 MOhm at 48 V DC
Weight approx.
0.5
kg
EMC
89/336/EEC and 95/54/EEC