5 Gas Valves E-LES
24
KRONOS 20
5.2
Technical Data
All inputs and outputs are reverse polarity protected and short-circuit-proof against battery
plus and minus.
5.2.1
Specifications for all E-LES Gas Valves
Power supply
12 V DC or 24 V DC
Min. voltage
10 V DC
Max. voltage
32 V DC
Residual ripple
max. 10 % at 100 Hz
Current consumption
max. 1.5 A
Admissible voltage drop
max. 10 %
at max. power consumption
Fuse 6
A
Stepping motor frequency
500 Hz
Storage temperature
-40°C to +85°C
Ambient temperature during operating
-20°C to +80°C
Air humidity
up to 98 % at 55°C
Admissible pressure of fuel supply
max. 0.1 bar
Admissible concentration of
hydrogen sulphide (H
2
S) in fuel
max. 0.1 %
Vibration
max. 2 m/s at 10..20 Hz
max. 0.24 m/s at 21..63 Hz
max. 9 g at 64..2000 Hz
Shock
50 g, 11 ms, half sine
Protection grade
IP 55
EMC
89/336/EEC and 95/54/EEC
Connection
DIN 45321; 7 pin male
Gas valves E-LES might only be used as control valves!
Never use as shut-off valve!