7 Technical data
Positioner DC 6-06
41
7.3
Terminal connection diagrams
All of the terminal connection variants described in this publication are illustrated
schematically below.
They differ in the type of setpoint selection, the stop signal and the actuator.
The setpoint selection can be analogue using a setpoint potentiometer or a current or
voltage signal. PWM setpoint selection is also possible. Setpoint selection by a CAN
protocol can also be implemented on request.
The stop signal can be selected digitally or analoguely by a current or voltage signal.
Digital inputs are not monitored for errors and must
not be used for safety-related functions as defined by
classification societies
Therefore it is recommended to use a monitored analogue
input instead of a digital input for the external stop request
(
5.2.1.2 External stop request by an analogue input).
In the diagrams, the actuators are distinguished according to those with a disc rotor motor
and gearless actuators. The former type include StG 6 to StG 40, for example. The fast
2000 series actuators, linear actuators or the Bosch-EDC can be used in the gearless
version.