11 Parameter description
72
Positioner DC 6-06
11.2
List 1: Parameter
No. Name
Meaning
310
ActPosSecureMin
Level:
6
Range: 0..100
%
Page(s):
Minimum control path to protect the actuator from
mechanical and thermal stress (approx. 3 %)
312
ActPosSecureMax
Level:
6
Range: 0..100
%
Page(s):
Maximum control path to protect the actuator from
mechanical and thermal stress (approx. 97 %)
331 FuelSetpSubst
Level:
4
Range: 0..100
%
Page(s):
Equivalent value for the setpoint generator in case of
error
340
AnaStopThresholdLow
Level:
6
Range: 0..100
%
Page(s):
Definition of the lower threshold for the stop request
via analogue input
341
AnaStopThresholdHigh
Level:
6
Range: 0..100
%
Page(s):
Definition of the upper threshold for the stop request
via analogue input
342
AnaStopSensorSubst
Level:
6
Range: 0..100
%
Page(s):
Equivalent value for the analogue stop sensor in case of
error
810
FunctStopRequest
Level:
6
Range: 0..5
Page(s):
Configuration of the stop request via a digital input
828
FunctErrorReset
Level:
6
Range: -5..5
Page(s):
Configuration of the error reset function via a digital
input
845
FunctAutoAdjust
Level:
6
Range: -5..5
Page(s):
Configuration of the auto adjust function via a digital
input
1500
FuelSetPWMIn1RefLow
Level: 4
Range: 0..100
%
Page(s):
Lower reference value of PWM input 1 for setpoint
selection