11 Parameter description
Positioner DC 6-06
73
No. Name
Meaning
1501
FuelSetPWMIn1RefHigh
Level: 4
Range: 0..100
%
Page(s):
Upper reference value of PWM input 1 for setpoint
selection
1504
FuelSetPWMIn3RefLow
Level: 4
Range: 0..100
%
Page(s):
Lower reference value of PWM input 3 for setpoint
selection
1505
FuelSetPWMIn3RefHigh
Level: 4
Range: 0..100
%
Page(s):
Upper reference value of PWM input 3 for setpoint
selection
1506
FuelSetPWMIn1_Filter
Level: 4
Range: 1..255
Page(s):
Filter for PWM input 1 for setpoint selection
1508
FuelSetPWMIn3_Filter
Level: 4
Range: 1..255
Page(s):
Filter for PWM input 3 for setpoint selection
1510 AnaStop_Ref_0%
Level:
4
Range:
0.. 5V
or 0..22 mA
Page(s):
0 % reference value of the analogue input for the stop
request
1511 AnaStop_Ref_100%
Level:
4
Range:
0.. 5V
or 0..22 mA
Page(s):
100 % reference value of the analogue input for the stop
request
1512 AnaStop_ErrorLow
Level:
4
Range:
0.. 5V
or 0..22 mA
Page(s):
Error limit for minimum value of the analogue input for
the stop request
1513 AnaStop_ErrorHigh
Level:
4
Range:
0.. 5V
or 0..22 mA
Page(s):
Error limit for maximum value of the analogue input for
the stop request
1514 AnaStop_Filter
Level:
4
Range: 1..255
Page(s):
Filter value of the analogue input for the stop request