11 Parameter description
78
Positioner DC 6-06
11.3
List 2: Measured values
Name
Meaning
2300 ActPos
Level:
1
Range: 0..100
%
Page(s):
Current actuator position
2330 ActPosSetpoint
Level:
1
Range: 0..100
%
Page(s):
Control path setpoint for the actuator
2350
FuelSetpoint
Level:
1
Range: 0..100
%
Page(s):
Setpoint
2809
AnaStopRequest
Level:
1
Range: 0/1
Page(s):
State of the stop request via analogue input
2810
SwitchStopRequest
Level:
1
Range: 0/1
Page(s):
State of the stop request via digital input
2828
SwitchErrorReset
Level:
1
Range: 0/1
Page(s):
State of the switch function “Error reset”
2845
SwitchAutoAdjust
Level:
1
Range: 0/1
Page(s):
State of the switch function “Automatic actuator
adjustment”
2900
AnaStopSensor
Level:
1
Range: 0..100
%
Page(s):
Current measured value of the analogue stop input
3000 ConfigurationError
Level:
1
Range: 0..65535
Page(s):
Displays configuration errors
3005 ErrAnaStopRequest
Level:
1
Range: 0/1
Page(s):
Error display of the analogue stop input
Summary of Contents for PANDAROS DC 6-06