11 Parameter description
Positioner DC 6-06
85
11.4
List 3: Functions
Name
Meaning
4330 ChanTyp_FuelSetp
Level:
6
Range: 0..10
Page(s):
Configuration of the input channel type of the setpoint
generator
0 = analogue
1 = PWM
(RESET)
4331 SubstOrLastFuelSetp
Level:
4
Range: 0/1
Page(s):
Selection of the equivalent value for the setpoint
generator in case of error (0 = last valid value,
1 = equivalent value 331
FuelSetpSubst
)
(RESET)
4332 HoldOrResetFuelSetp
Level:
4
Range: 0/1
Page(s):
Selects whether the error at the setpoint generator is
reset or held when the signal returns
(0 = error cleared, 1 = error retained)
(RESET)
4335 ActPosOutPWMOrAnalog
Level:
4
Range: 0/1
Page(s):
Configuration of the output channel type for the display
of the current actuator position
0 = analogue
1 = PWM
(RESET)
4340 AnaStopRequestUsed
Level:
6
Range: 0/1
Page(s):
Activates the analogue stop request
(RESET)
4341 AnaStopSubstOrLast
Level:
6
Range: 0/1
Page(s):
Selects the equivalent value for the analogue stop
request in case of error (0 = last valid value,
1 = equivalent value 1000
AnaStopSensorSubst
)
(RESET)
4342 AnaStopHoldOrReset
Level:
6
Range: 0/1
Page(s):
Selects whether the error at the analogue stop request is
reset or held when the signal returns
(0 = error cleared, 1 = error retained)
(RESET)
4721 FuelToActPosCurveOn
Level:
4
Range: 0/1
Page(s):
Activates the filling-dependent actuator nominal
position (curve)
(RESET)
Summary of Contents for PANDAROS DC 6-06