 HEIKO POLE V1 Feb 2019 

 

Page 

2

 of 

2

 

 

 

 

INSTALLATION OF  HEIKO POLE TOWEL WARMER 

 

SPECIFICATIONS 

Mounting Centre 

(Approx Width) 

Rating at 240 Volts AC 

Voltage 

IP Rating 

WHSP1000    Polished stainless steel 

800 mm 

20 watts 

230-240VAC 

IP45 

WHSP1000N Black  

800 mm 

24 watts 

230-240VAC 

IP45 

 

This Package Contains: 

1  Towel Warmer    

 

 

 

 

 

2 x Mounting blocks(legs) and  one wall bracket and one mounting block.  

 

2 x Mounting Screws to fix wall bracket to wall    

 

 

 

 

CAUTION: 

Prior to installation please ensure the product is to your satisfaction. Once installed Heirloom cannot be responsible for 

defects in the product finish. This product is not intended for use by young children or infirmed persons without supervision. In order to 
avoid a hazard for very young children, this towel warmer should be installed at least 600mm from the floor. Young children should be 

supervised to ensure they do not play with the product. If the supply cord is damaged it must be replaced by the manufacturer, its service 
agent, or similarly qualified persons in order to avoid a hazard. 

 

Installation: 

The Strata Heiko Vertical is intended for installation in a vertical orientation, though horizontal installation is also acceptable.  
This towel warmer must be installed by a registered electrician and in accordance with local and national electrical codes. We 

recommend that the towel warmer be installed vertically on a flat and uniform wall, and where possible into studs or other suitable 
anchor material. If fixing to hollow cavity walls, toggle anchors (not those supplied) or similar devices must be used. 

 

Position the towel warmer so that the  mains power source is  easily accessible. Cable entry to the towel warmer can be top or bottom 
(or left or right.  Avoid the supply cable coming into contact with the heated parts of the towel warmer where installation is with exposed 
flex. .  

 

DO NOT APPLY POWER TO THE UNIT,  OR SWITCH THE TOWEL WARMER ON BEFORE INSTALLATION IS COMPLETE. 
 
EXPOSED FLEX INSTALLATION: (Fig 1) 

Identify suitable mounting points, preferably into timber framing. Where this is not possible, use toggles (not supplied) . 

Mounting centres are 800mm vertically (can be installed horizontally). Screw  flex bracket and mounting block to the wall. 

 

Thread t

he “Flex Leg” 

(with plastic grommet) on to the electric flex (ensuring that the leg is facing in the correct direction).  Fix 

the leg to the towel warmer with the two screws provided.

 

Ensure the flex exits the leg through the slot with the plastic grommet. Place the towel warmer on to the two mounting blocks 

and tighten grub screws

 

Connect flex to switch at flush box (termination pack supplied may be used)

 

 

CONCEALED FLEX INSTALLATION (Fig 2) 
 

As above, except that the flex will pass though the hole in the wall bracket.  

     

 

 
Fig 1 Exposed wiring 

 

 

 

     Fig 2 Concealed wiring 

 
 

 