20
Description of the parts of the electric resistance
and thermostat
21
Plastic cover
22
Electric resistance
22A
Thermostat’s socket
22B
Resistance’s cover
23
Base of multiple plug (for the elec
-
tric lines)
24
Metal wires for the connections of
the resistance with the thermostat
25
Rubber flange for water tightness
26
Central nut
27
Tightening nuts
28
Grounding lug
29
Electric resistance’s lug
30
Grounding wire
31
Power wire
32
Multiple plug for power lines
33
Thermostat
34
Temperature control
35
Safety thermal switch (indication
“F” or “S”)
CONNECTION OF THE CABLES
1.
Turn off the power main supply.
2.
The cover of the electric resistance is on the right hand side of the
storage tank. Unscrew the two screws and remove the cover.
3.
The thermostat is adjusted from the factory at 60
o
C. You can
adjust it at the temperature you wish, by using the temperature
control (34). In that case we advise that the temperature you will
fix not to exceed 75
o
C.
4.
Check the safety thermal switch (indication “F” or “S”) on the ther
-
mostat. The safety switch is in operation when it is pushed in.
DIAGRAM OF ELECTRIC
CONNECTION OF THE
THERMOSTAT
29
22B
22A
22
25
28
26
34
35
33
24
27
32
24
27
29
29
23
30
1
2
3
4
30
50
60
70
80
N L
22A
230 V
aC
1 2 3
4
RESISTANCE