m
We recommend a max. volume flow of 600 m³/h, otherwise the Hepa14 filter loses efficiency and separates less.
6�1 Air Purifier control with fan EC 0… 10V
Please read this instruction manual carefully before using the product.
The control panel (Fig.5) has 4 buttons:
ON / OFF, MODE, UP
and
DOWN
.
m
If the backlight is off, the first press (on any button) turns the backlight on� With the backlight on, the
functions of the buttons are as described below� The backlight automatically turns off after 2 minutes without
pressing�
Basic functions:
ON / OFF:
Short press: Selects the regulator on / off status. Manual mode.
Long press (approx 1s): Activates and deactivates the time programming.
Schedule off: Manual mode
Schedule activated: Operation by time programme.
GO UP:
Short / long press: Increase the speed setpoint (0% ... 100%).
GO DOWN:
Short / long press: Decrease the speed setpoint (100% ... 0%).
MODE:
Short press: Display of operating times (filters G4 and H14).
Long press (2s approx): Access the user menu:
•
Date setting (HOrA)
•
Time programming (PrOG)
•
Identifier display (id)
•
Parameter mode (PAr)
•
Reset of filter operating time G4 (r g4)
•
Reset del tiempo de funcionamiento filtro H14 (r h 14)
•
Regulator reset (rESET).
User Menu:
- With UP and DOWN you select the mode to access. To enter the selected mode, press MODE. To exit press ON /
Air purifier AirPal Go 600 H
Surface
(m²)
Q max�
(m³/h)
Setpoint
Control voltage
(V)
Power
(W)
Current (A)
30
400
53
5,3
33,38
0,37
37,5
500
61
6,1
52,48
0,51
45
600
70
7,0
78,23
0,70
52,5
700
81
8,1
111,72
0,96
60
800
95
9,5
154,10
1,29
62,5
833
100
10,0
170,39
1,42