background image

2

 EN

      EN    

Tamper Protection Kit 

AirPal-IVSS

Installation and Operating Instructions

m

 

Danger to life

The electrical connection of the AirPal unit must be fully isolated from the mains power sup-

ply until final assembly.

2.1 Cover assembly

1. Unpack the tamper protection kit 

AirPal-IVSS

 and remove the cover with the  

plexiglass top.

2. Use the key to unlock the plexiglass top and remove it from the cover.

3. Remove the screws in the corners of the control panel.

CHAPTER 2   

 

INSTALLATION

m

 DANGER

Fig.1 

 

Fig.2 

 

Fig.3 

 

Summary of Contents for AirPal-IVSS

Page 1: ...Interventionsschutz Set Tamper Protection Kit AirPal IVSS f r AirPal Standger te for AirPal tower units Helios Ventilatoren MONTAGE UND BETRIEBSVORSCHRIFT INSTALLATION AND OPERATING INSTRUCTIONS EN DE...

Page 2: ...der Ma nahmen zu Sachsch den f hren k nnen 1 3 Garantieanspr che Haftungsausschluss Wenn die nachfolgenden Ausf hrungen nicht beachtet werden entf llt unsere Gew hr leistung Gleiches gilt f r Haftungs...

Page 3: ...g 1 Packen Sie das Interventionsschutz Set AirPal IVSS aus und entnehmen Sie die Abdeckung mit dem Plexiglasaufsatz 2 Verwenden Sie den Schl ssel um den Plexiglasaufsatz zu entriegeln und von der Abde...

Page 4: ...ung 5 Positionieren Sie die Abdeckung ber das Bedienfeld Die Schraubenl cher sollten auf gleicher Position liegen 6 Zur Befestigung der Abdeckung nutzen Sie die zuvor entfernten Schrauben Abb 3 7 Setz...

Page 5: ...s muss vor der T Griff Montage entfernt wer den Die Schritte zur Demontage sind unten dargestellt Es wird empfohlen den obersten Verriegelungsmechanismus durch den T Griff zu ersetzen 1 Entfernen Sie...

Page 6: ...iffs Nach der Demontage des vorhandenen Verriegelungsmechanismus wird der T Griff wie folgt montiert 1 Bauen Sie den T Griff auseinander Abb 11 2 Nehmen Sie das Teil 4 der Verriegelungsk rper und schi...

Page 7: ...il 5 die Geh usemutter auf und ziehen Sie sie mit einem Schraubenschl ssel fest 4 Schieben Sie das Teil 2 den Verriegelungsmechanismus mit dem Teil 3 der O Ring in den Verrriegelungsk rper ein 5 Setze...

Page 8: ...7 DE Interventionsschutz Set AirPal IVSS Montage und Betriebsvorschrift 6 Montieren Sie das Teil 6 das Verschlussteil mit dem Teil 7 die Schraube Abb 16...

Page 9: ...followed m CAUTION Indicates dangers which can result in injuries if the safety instruction is not followed ATTENTION Indicates dangers which can result in material damage if the safety instruction i...

Page 10: ...lly isolated from the mains power sup ply until final assembly 2 1 Cover assembly 1 Unpack the tamper protection kit AirPal IVSS and remove the cover with the plexiglass top 2 Use the key to unlock th...

Page 11: ...n the plastic cable clamp on the cover 5 Position the cover over the control panel The screw holes should be in the same position 6 Use the previously removed screws Fig 3 to attach the cover 7 Place...

Page 12: ...sm The existing locking mechanism must be removed before installing the T handle The disassembly steps are shown below It is recommended to replace the top locking mechanism with the T handle 1 Remove...

Page 13: ...ont side of the unit 2 2 2 T handle assembly After disassembling existing locking mechanism the T handle is mounted as follows 1 Disassemble the T handle Fig 11 2 Take part 4 the locking body and inse...

Page 14: ...on and Operating Instructions 3 Place part 5 the body nut on and tighten it with a spanner 4 Insert part 2 the locking mechanism with part 3 O ring into the locking body 5 Insert part 1 the T handle i...

Page 15: ...Tamper Protection Kit AirPal IVSS Installation and Operating Instructions 7 EN 6 Mount part 6 the locking part with part 7 the screw Fig 16...

Page 16: ...D HELIOS Ventilatoren GmbH Co KG Lupfenstra e 8 78056 VS Schwenningen F HELIOS Ventilateurs Le Carr des Aviateurs 157 av Charles Floquet CH HELIOS Ventilatoren AG Tannstrasse 4 8112 Otelfingen 93155...

Reviews: