23 / 179
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without
express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.
21.04.2020
Version 1.18.0
Structure and function
APS-90, APS-180 and APS-90-Outdoor-PoE
Fig. 15: Connecting the reset
pin on an APS-90-Outdoor-
PoE
3.1.5
Factory reset button/pin
The device must be powered for using the button/pin.
On an APS-90 or APS-180 press the button gently with a pencil.
On an APS-90-Outdoor-PoE connect the reset pin 1 of the I/O port with pin 12.
The device will change the LED illumination as feedback.
There are two options, depending how long the button is pressed or the pin is connected:
■
Factory Reset pressing the button/connecting the pin more then 5 second if LED illu-
minated in yellow.
■
Fallback System pressing the button/connecting the pin less then 5 second while LED
illuminated in blue.
By the ‘Factory Reset’ all settings (including network settings) restored to the factory
defaults. The device reboot. This reboot takes more time as a normal startup.
At the ‘Fallback System’ the APS is started only with a basic emergency system in DHCP
mode. The LED illuminated in red during the whole time. You could connect to a simple
user interface, that allow you to:
■
Update the firmware.
■
Set the IP setting to use DHCP.
■
Set the device to the factory default settings (factory reset).
■
Display diagnosis data.
■
Reboot the device.