44 / 179
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without
express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.
21.04.2020
Version 1.18.0
Structure and function
APS-90, APS-180 and APS-90-Outdoor-PoE
Countevent data
Example
Data file recording settings:
Completion interval
15 min
record_id timestamp
period
status
line
event_typ
e
id
class
0
2020-04-01 14:30:15 216
"0"
Polyline0
Out
1740
Adult
1
2020-04-01 14:30:18 219
"0"
Polyline0
Out
0
Group
2
2020-04-01 14:35:19 455
"0"
Polyline0
In
1850
Adult
3
2020-04-01 14:35:11 507
"0"
Polyline0
In
0
Group
record_id:
Unique ID for sample interval scanning cycle
(after ID 4294967295 it restarts with 0)
timestamp:
Timestamp of device is adjusted to the local time of the
scanning cycle
period:
Time since last record
status:
OSD status - see values below
0 OK
1 Error: covered
(e.g. one sensor covered)
3 Error: illumination is too dark
5 Error: illumination is too bright
line:
Name of the counting line
event_type:
Type of the counting event
"In" or "Out"
id:
Unique ID for the object
class:
Classification Adult/Child/Group/Cart of the object