67 / 179
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without
express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.
21.04.2020
Version 1.18.0
Installation
APS-90, APS-180 and APS-90-Outdoor-PoE
Table 1: Monitored area (detailed information
Chapter 9.1 Detection area on page 151
Installation height
Width (X)
Depth (Z)
[m]
[ft]
[m]
[ft]
[m]
[ft]
2.00
6.56
1.85
6.07
1.60
5.25
3.00
9.84
3.90
12.80
3.30
10.83
4.00
13.12
6.00
19.69
5.05
16.57
5.00
16.40
8.00
26.25
6.80
22.31
6.00
19.69
8.00
26.25
8.00
26.25
5.2
Mounting the APS-90
5.2.1
Surface mounting
1
1
1
1
Fig. 46: Fixing Points
Fix the APS-90 surface mount box to the ceiling.
Attach the ethernet cable to the APS-90
Fig. 47: Mount the device into the mount box
1.
2.