APS-90, APS-180 and APS-90-Outdoor-PoE
Digital output with potential-
free contacts
The following examples shows wiring diagrams for the potential-free
digital output contacts.
Observe the following electrical limit values:
I
max
= 100 mA
U
max
= 30 VDC
Fig. 58: APS-Outdoor Digital output with potential-free contacts
Fig. 59: APS-Outdoor Digital output with buzzer
Fig. 60: APS-Outdoor Digital output with relay