65 / 179
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without
express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.
21.04.2020
Version 1.18.0
Installation
APS-90, APS-180 and APS-90-Outdoor-PoE
Mounting position
5
Installation
5.1
Requirements
Consider the following requirements when selecting the mounting position:
Fig. 44: Mounting position
■
Ensure that the mounting position and the holder / protective housing provide suffi-
cient stability.
■
Ensure that the mounting position is in the right place:
●
As much as possible, the view between the device and people's heads should be
unobstructed.
●
As much as possible, the monitored area (Fig. 44 /2) must be free of interfering
objects.
●
The flow of persons in a monitored area should be through the center.
●
Place the device (Fig. 44 /1) above the end of the door swing area, because the
counting lines must be set around that door swing area.
●
Place the device at least 30 to 50 cm (11.8 to 19.7 in) away from a wall with
sliding doors, because a minimum clearance of 30 to 50 cm (11.8 to 19.7 in)
(Fig. 44 /A) must be observed between the counting lines (Fig. 44 /3) and the
entrance for tracking people.
●
For counting line applications there must not be any point of interest (Fig. 44 /4)
in the counting area, i.e. no place where people are encouraged to linger (sales
counter, coat stands, info stands, etc.), because tracking may be lost e.g. due to
persons bending down or interacting with objects
■
Ensure that there are no sight restrictions.