LED modules are polarity conscious.
Reverse polarity will not damage this product but will
inhibit its function.
HELLA recommends wire connections be soldered, and
heat shrink tubing applied to seal the joint.
Note:
Lamp must be protected by a fuse rated at 5
amperes maximum.
Wiring Colour Coding
Colour
Connect to
Black
Negative (-ve)
Red
Signal (+ve)
Assembly
Step 3 – Insert the optic assembly
Note: Arrow on top of shroud and arrow on top of
optic assembly must point in the same direction.
3.1 Feed power cable through shroud
3.2 Push optic assembly into shroud
3.3 Connect power
Step 2
Pull optic assembly out.
Step 1
Carefully insert 2 screw drivers between
optic assembly and shroud.
Removal
Note: Do not open. No servicable parts
inside.
www.hellamarine.com
Step 2 – Mount the Shroud
2.1 Shroud must be installed with markings on
the top horizontal surface.
2.2 Arrow on top of shroud must point straight
ahead.
2.3 Fix shroud with two M5 or 10 gauge fasteners.
Step 1 – Make provision for the power cable
Use mounting shroud as a template to drill screw
holes and make provision for the cable.
Cable exit
Screw hole
Screw hole
Markings on the top
Use marine grade
stainless steel fasteners
with a wide flat head
(not included)
Shroud
Optic Assembly
General recommendations
When the lamp is operating, the light should not
be obstructed or concealed by superstructures
or other objects.
Position in relation to vessels centre line
The lamp must be positioned in a vertical
position at a right angle to the vessel's centre
line with the signal direction arrow pointing
straight ahead. (see Fig. 1)
Horizontal positioning
The lamp must be placed forward of amidships
and as far forward as practicable.
(see Fig. 2)
Fig. 1 Right angle to the vessel's centre line
Fig. 2 Horizontal positioning
Top view
Lamp positioning
2LT 959 940
Made in New Zealand
TOP
Amidship