Installation instructions and Instructions for use
Subject to technical modifications
–
Date of Issue April/2022
25
Installation on concrete
Installation of the anchor bolts as per
approval ETA-05/0069:
- Drilled hole preparation ø12 mm
Installation of the attachment:
- Tightening torque as per ETA-
05/0069
Legend
Concrete
Installation set 1; anchor bolt FAZ II M12
Bracket
Minimum anchoring depth - 70 mm
1
2
3
4
Installation instructions and Instructions for use
26
Subject to technical modifications
–
Date of Issue April/2022
Installation on concrete up to 60 mm ETICS
Installation of the anchor rod as per
approval ETA-12/0258:
- Drilled hole preparation ø14 mm
- Observe the anchoring depth and
the minimum edge distance!
- Drilled hole cleaning
- Fill drilled hole with mortar FIS SB
- Slide the anchoring element into
the drilled hole
- Wait for the curing time
Installation of the attachment:
- Cut free lock nut in the ETICS
- Align lock nuts
(1 mm before the plaster level) and
then seal the expansion joint
- Cut the threaded rod to the correct
length
- Screw down the bracket
Legend
Concrete
Thickness of the non-bearing layer
<60 mm
Installation set 8; anchor rod M12
Anchoring depth 140 mm = drilled
hole depth
ETICS
Lock nut + washer
Bracket
1
2
3
4
5
6
7
Installation instructions and Instructions for use
Subject to technical modifications
–
Date of Issue April/2022
27
Installation on concrete 60-200 mm ETICS
Installation of the anchor rod as per
approval ETA-02/0024:
- Drilled hole preparation ø18 mm
- Observe the anchoring depth and
the minimum edge distance!
- Drilled hole cleaning
- Fill drilled hole with mortar FIS V
- Slide the anchoring element into
the drilled hole
- Wait for the curing time
Installation of the Thermax as per
approval Z-21.8-1837:
- Mill open the thermal insulation
prior to injection
- Sealing of the expansion joint
Installation of the attachment:
- Tightening torque as per Z-21.8-
1837
- Sealing of the free elongated hole
parts
Legend
Concrete
Bracket
Installation set 3; Thermax 16/170
M12
Thickness of the non-bearing layer
up to 200 mm
ETICS
Anchoring depth 140 mm = drilled
hole depth
Depending on the thickness of the non-bearing layer, different brackets
must be used (60-170 mm; 170-200 mm).
1
2
3
4
5
6
Installation instructions and Instructions for use
28
Subject to technical modifications
–
Date of Issue April/2022
Installation on brickwork
Installation of the anchor rod as per
approval ETA-10/0383:
Depending on the type of stone, the
injection anchor sleeve must be used!
- Drilled hole preparation
ø12 mm without sleeve
ø16 mm with sleeve (16x130)
- Drilled hole cleaning
- Fill drilled hole (anchor sleeve) with
mortar FIS V
- Slide the anchoring element into
the drilled hole
- Wait for the curing time
Installation of the attachment:
- Tightening torque as per ETA-
10/0383
Legend
Brickwork
Installation set 2; anchor rod M10
Bracket
Anchoring depth 130 mm
drilled hole depth
1
2
3
4