Quickstart Guide FLEXtra PROFINET-Switch | Version 1 | 17.09.2020
8
4.5
Further configuration and diagnosis via the web interface
Via the web interface, the status of the PROFINET switch can
be queried and further functions can be configured.
Furthermore, a firmware update can be performed via the web
interface.
The web interface can be operated as soon as the device has a
network configuration. The IP address of the device must be
entered as URL.
In the following login dialog the username is "admin" and the
password is the serial number of the PROFINET switch which
can be read at the device side. For the first login the default
password must be changed.
Further information about the web interface can be taken
from the manual.
5
Diagnosis via LEDs
5.1
System LEDs
PWR
Off
No power supply or device defective
On
Device is correctly supplied with voltage
RUN
On
Device is ready to operate
Flashing
Device is starting up
Flashing synchronous with BF and SF LED
PROFINET function device identification
BF
On
Bus error, no configuration
Flashing synchronous with RUN and SF LED
PROFINET function device identification
SF
On
System error, network status in error
Flashing synchronous with RUN and BF LED
PROFINET function device identification
5.2
Ethernet LEDs P1 – P16 (RJ45)
Off
No network cable connected or network cable defective or partner device off
Green
On
Ethernet connection with 10/100 Mbit/s
Flashing
Ethernet communication with 10/100 Mbit/s
Orange
On
Ethernet connection with 1000 Mbit/s
Flashing
Ethernet communication with 1000 Mbit/s