WALL IE, Industrial Ethernet Bridge and Firewall | Version 1 | 15.05.2017
11
2.2
Connection of the power supply
The WALL IE is connected with 24 V DC voltage via the 5-pin power supply socket. There is also a
connection for the functional ground (FG). The connection of a functional ground is recommended.
The inputs IN1 and IN2 do not yet have a function in the current firmware version, but will be
available in a later firmware version for the external switching of firewall rules.
2.3
LEDs status information
PWR
Off
No power supply or device defective.
On
Device is correctly supplied with voltage.
RDY
On
Device is ready to operate.
ACT
Flashing light or
ON
Data transfer permitted between WAN and LAN.
USR
On
Factory settings reset active.
RJ45 LEDs
Green (Link)
Connected
Orange (Act)
Data transfer at the port