1 – Degree Mode
Value
Description
How to Read and Write
Dec
Hex
Available
settings
0
1
0x00
0x01
°C – Celsius
°F –
Fahrenheit
Read:
Command = CONFIGURATION_GET
Parameter Number = 1 (0x01)
Report is returned.
Write:
Command = CONFIGURATION_SET
Parameter Number = 1 (0x01)
Default settings
0
0x00
°C
Parameter size:
1 byte
2 – Source Sensor
Value
Description
How to Read and Write
Dec
Hex
Available
settings
0
1
2
3
4
5
6
0x00
0x01
0x02
0x03
0x04
0x05
0x06
F – Floor sensor
FA – Floor+Air sensors
A – Air sensor
AF – Air+Floor sensors
P – Time regulation
PF – Time+Floor sensor
PA – Time+Air sensor
Read:
Command = CONFIGURATION_GET
Parameter Number = 2 (0x02)
Report is returned.
Write:
Command = CONFIGURATION_SET
Parameter Number = 2 (0x02)
Default settings
0
0x00
F
Parameter size:
1 byte
3 – Power Regulation ON time
Value
Description
How to Read and Write
Dec
Hex
Available
settings
10
-
90
0x0A
-
0x5A
Minutes
Read:
Command = CONFIGURATION_GET
Parameter Number = 3 (0x03)
Report is returned.
Write:
Command = CONFIGURATION_SET
Parameter Number = 3 (0x03)
Default settings
15
0x0F
15 min
Parameter size:
1 byte
4 – Power Regulation OFF time
Value
Description
How to Read and Write
Dec
Hex
Available
settings
10
-
90
0x0A
-
0x5A
Minutes
Read:
Command = CONFIGURATION_GET
Parameter Number = 4 (0x04)
Report is returned.
Write:
Command = CONFIGURATION_SET
Parameter Number = 4 (0x04)
Default settings
15
0x0F
15 min
Parameter size:
1 byte
5 – Air Temperature Minimum
Value
Description
How to Read and Write
Dec
Hex
Available
settings
40
-
360
0x28
-
0x0168
(Value/10),
Temperature in
Celsius
Read:
Command = CONFIGURATION_GET
Parameter Number = 5 (0x05)
Report is returned.
Write:
Command = CONFIGURATION_SET
Parameter Number = 5 (0x05)
Default settings
210
0xD2
21.0
°
C
Parameter size:
2 byte