background image

TECHNICAL SPECIFICATIONS:

 

 

Front frame dimensions: 89х89х9mm 

 

Back dimensions: 53х53х28mm  

 

Material: Flame retardant plastic, tempered glass 

 

Colour: silver frame, black or white glass 

 

LCD: 73x42mm, black with white icons 

 

4 sensitive capacitive touch buttons 

 

Operating temperature

: -10°С – +40°С 

 

Power supply: 100V – 230VAC, 50Hz/60Hz 

 

Power consumption: 1.5W 

 

Maximum resistive load: 16А  3600W 

 

Relay life time: 100.000 switches 

 

Internal temperature sensor 

o

 

Measurement range:  -40°C to +125°C 

o

 

Accuracy

: ±0.5°C

 

 

 

Internal humidity sensor 

o

 

Measurement range: 0 – 80%RH 

o

 

Accuracy

: ±3.0%RH  

 

External floor temperature sensor 

o

 

NTC 10kOhm 

o

 

Measurement range:  -30°C to +80°C 

o

 

Accuracy

: ±0.5°C

 

 

 

Energy consumption meter 

 

IP class: IP21 

 

Z-Wave frequency: EU-868/869 MHz  
(other frequencies available on request) 

 

Z-Wave SDK: V6.51.06

 

 

Z-Wave Plus module: ZM5202 

 

FUNCTIONAL SPECIFICATIONS (FEATURES): 

 

Inclusion/exclusion into/from z-wave network 

 

Association control of 10 devices from network 

 

4 operation modes: ECO, GEN, DRY, MANUAL 

 

Choosing a temperature sensor for operation 

 

Floor temperature only 

 

Air temperature only 

 

Floor + Air temperature 

 

Power regulator (Automatic ON/OFF timer) 
Time cycle: 10-90 minutes 

 

Usable with different NTC-sensor  

 

Temperature sensors calibration 

 

Temperature set intervals: 4°C to 37°C 

 

Temperature limiter 

 

Choosing a temperature hysteresis 

 

Choosing a degree  (Celsius / Fahrenheit) 

 

Adjustable LCD brightness 

 

LCD standby mode 

 

Child lock 

 

Consumption meter reset 

 

Factory reset 

 

OTA function (Firmware update over the air). 

Z-WAVE CLASSES: 

CLASSES GENERIC_TYPE_THERMOSTAT  
SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2 
COMMAND_CLASS_BASIC  
COMMAND_CLASS_THERMOSTAT_SETPOINT_V3 
COMMAND_CLASS_THERMOSTAT_SETBACK 
COMMAND_CLASS_THERMOSTAT_MODE_V3 
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE 
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 
COMMAND_CLASS_VERSION  
COMMAND_CLASS_MANUFACTURER_SPECIFIC 
COMMAND_CLASS_ZWAVEPLUS_INFO 
COMMAND_CLASS_METER_V3 
COMMAND_CLASS_DEVICE_RESET_LOCALLY 
COMMAND_CLASS_POWERLEVEL 
COMMAND_CLASS_CONFIGURATION_V2 
COMMAND_CLASS_ASSOCIATION  
COMMAND_CLASS_ASSOCIATION_GRP_INFO 
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V3

 

 

Summary of Contents for HE-ZW-THERM-FL1

Page 1: ...FLOOR HEATING THERMOSTAT HE ZW THERM FL1 USER MANUAL...

Page 2: ...in room air temperature sensor The thermostat is also equipped with built in humidity and energy consumption sensors The thermostat has a built in 5th generation Z Wave module which allows to integrat...

Page 3: ...ork 4 operation modes ECO GEN DRY MANUAL Choosing a temperature sensor for operation Floor temperature only Air temperature only Floor Air temperature Power regulator Automatic ON OFF timer Time cycle...

Page 4: ...o the wall mounting box using the screws provided Install the thermostat body by carefully aligning the top snap connectors and then pushing on the front cover with gentle pressure ensuring it snaps f...

Page 5: ...table MODE This mode is recommended for normal comfort Factory default set point is 25 0 C 77 F Minimum set point is 4 0 C 39 F Maximum set point is 37 0 C 99 F ECO energy saving MODE You can use this...

Page 6: ...02 SEn Source Sensor F F FA A AF P PF PA 03 Pon Power Regulation ON time min 15 10 90 04 PoF Power Regulation OFF time min 15 10 90 05 AIL Air Temperature Minimum C F 21 70 4 36 in Celsius mode 39 99...

Page 7: ...aram 03 Pon and then OFF during the time in Param 04 Pof 6 PF Power regulator Floor sensor parameters Parameter is heating time set by Params 03 and 04 but also controlled by the floor temperature sen...

Page 8: ...r 08 FLH Floor Temperature Maximum Floor temperature high limit Reading of the external floor temperature sensor It has effect only if AF or PF are selected as the source sensor Factory default value...

Page 9: ...ines the brightness level of the display in the inactive state You can select the level from values 1 to 4 but the level cannot be higher than the level of brightness for the active state Default valu...

Page 10: ...r appear in the value position then the inclusion was not completed Note In case the device has been part of a system before and not excluded since inclusion is not possible In this case exclusion mus...

Page 11: ...3 Power Regulation ON time Value Description How to Read and Write Dec Hex Available settings 10 90 0x0A 0x5A Minutes Read Command CONFIGURATION_GET Parameter Number 3 0x03 Report is returned Write Co...

Page 12: ...How to Read and Write Dec Hex Available settings 50 370 0x32 0x0172 Value 10 Temperature in Celsius Read Command CONFIGURATION_GET Parameter Number 8 0x08 Report is returned Write Command CONFIGURATIO...

Page 13: ...Available settings 5 95 0x5 0x5F Value 10 in Celsius 0 5 C to 9 5 C Read Command CONFIGURATION_GET Parameter Number 13 0x0D Report is returned Write Command CONFIGURATION_SET Parameter Number 13 0x0D...

Page 14: ...ure setpoint used in DRY mode Value 10 in Celsius 4 0 C to 37 0 C Read Command Class COMMAND_CLASS_THERMOSTAT_SETPOINT Command THERMOSTAT_SETPOINT_GET Type Dry air 0x08 Report is returned Write Comman...

Page 15: ...0x01 0x08 0x0B OFF GEN DRY ECO Read Command Class COMMAND_CLASS_THERMOSTAT_MODE Command THERMOSTAT_MODE_GET Report is returned Write Command Class COMMAND_CLASS_THERMOSTAT_MODE Command THERMOSTAT_MODE...