background image

1

Cierre el suministro de agua.

 

/ Close the water supply.

Requerimientos de

Instalación

Para el correcto funcionamiento de 
este producto, la presión mínima 
es de (0,6 kg/cm²) 8,53PSI.

Cada metro de altura de 
su producto a la base 
del tinaco equivalen a 
(0,1 kg/cm²) [1,42 PSI].

Hola soy Fluxy, te
ayudaré a instalar 
tu producto.

Instalación General

Monomando de Lavabo con Desagüe 

de Push

 

/ Single Control Faucet with 

Drain Push

Installation Requirements

For the correct operation of this 
product, the minimum pressure is 
(0,6 kg/cm²) 8,53 PSI.

Meter of height of your 
product to the base of 
the tub is equivalent to 
(0,1 kg/cm²) [1,42 psi].

Hi I'm Fluxy, I'll 
help you to install
 your product.

/ General Installation

E-920 

Alika

   INSTALLATION GUIDE

   GUÍA DE INSTALACIÓN

1-02-2757-4

Ubique y cierre las válvulas de suministro de agua.
Generalmente se encuentran debajo del lavabo. Si se trata de un 
reemplazo de grifo, quite el grifo viejo y limpie completamente la 
superficie del lavabo.

Locate and close the water supply valve.
Usually found under the sink. If it is a replacement faucet, remove 
the old faucet and clean the entire surface of the sink.

Herramienta Incluida en su Producto

/ Tools Included in your Product

Herramienta Requerida

perico

llave inglesa

teflón

/ Required Tools

wrench

plumbler

tape

adjustable 

wrench

hexagonal 

wrench

llave hexagonal

service key 

aereator

llave p/ aireador

5/64” hex key

llave allen 5/64”

llave de  

servicio.tecnico@helvex.com.mx

Original  Parts:

Consultancy and Technical

01(55)53339431

01800 909 2020

01 (55) 53 33 94 00 

Refacciones Originales:

Asesoría y Servicio Técnico:

Ext. 5068, 5815 y 5913

Service:

 53 33 94 21 

01 800 890 0594 

refacciones@helvex.com.mx

Monomando Alto de Lavabo con 

Desagüe de Push

 

/ Single Control 

High Faucet Mixer with Drain Push

E-921 

Alika

E-920 

E-921 

Relación

 Altura Tinaco-Presión

2,5 m

 6 m

 10 m

PSI

Altura (h)

 

3,55
8,53

14,22

kg/cm²

0,25

  0,6

1,0

Relation

 Tub Height-Pressure 

Height (h)

Accesorios Incluidos

/ Included Accessories

inserto

mantenimiento  

maintenance key

Para disminuir el riesgo de lesiones o daños a la propiedad, lea todas las instrucciones antes de instalar el 
producto. Utilice gafas de seguridad. En obras de construcción, instalación, modificación, ampliación y 
reparación deben cumplir con el  reglamento de construcción y obras de su localidad. El producto ilustrado 
puede sufrir cambios de aspecto como resultado de la mejora continua a la que  está sujeto.

Agradecemos su elección por los productos HELVEX. 
Estamos seguros de que su confiabilidad por el producto excederá sus más altas expectativas, cuya 
funcionalidad, estética, durabilidad, respaldo integral y alta calidad le otorgarán plena satisfacción por años, 
reflejando el compromiso con la calidad,  innovación y el medio ambiente que forman parte de Helvex.

Thank you for choosing HELVEX products.
We are confident that the product reliability will exceed your maximum expectations. The functionality, 
aesthetics, durability are at its highest quality! The comprehensive support will grant full satisfaction for years, 
reflecting the commitment to quality, innovation and the environment as part Helvex.

To reduce the risk of injury or property damage, read all instructions before installing the product. Please 
remember to use safety glasses. In construction, installation, alteration, extension and repair, the rules of 
constructions must be applied. As result of continuous improvement, the illustration product may change in 
appearance. 

ADVERTENCIA

 / WARNING

Esta guía de instalación  aplica al producto en cualquier acabado. / 

This installartion 

 guide applies to the product in any finish.

hot

cold

Caliente

Fría

*55 cm

(21,6”)

*20,3 cm

angle stops

válvulas 

angulares 

NPT

(8”)

*Medidas Recomendadas

(Nivel de Piso Terminado)

(Finished Floor Level)

insert basin 

without overflow 

*Recommended 

Summary of Contents for Alika E-920

Page 1: ...elación Altura Tinaco Presión 2 5 m 6 m 10 m PSI Altura h 3 55 8 53 14 22 kg cm 0 25 0 6 1 0 Relation Tub Height Pressure Height h Accesorios Incluidos Included Accessories inserto mantenimiento maintenance key Para disminuir el riesgo de lesiones o daños a la propiedad lea todas las instrucciones antes de instalar el producto Utilice gafas de seguridad En obras de construcción instalación modific...

Page 2: ...pes and then to angle stops Instalación de las Mangueras Installation of Hoses mangueras incluidas línea de alimentación hoses included separador shank gasket nut rondana tuerca washer Desenrosque la tuerca retire la rondana y el separador Unscrew the nut remove the washer and the shank gasket Coloque el separador la rondana y enrosque la tuerca con la llave incluida para sujetar la salida Place t...

Page 3: ...iones 14 Inst p Lav sin Rebosadero cubierta cover extensión superior uper extension empaque o rings inserto gasket insert cuerpo contra body drain 15 Enrosque nuevamente la extensión superior y cubierta Screw again the upper extension and cover extensión superior uper extension cubierta cover cuerpo contra con inserto body drain with insert Mantenimiento del Aireador Aereator Maintenance 16 airead...

Page 4: ... Mod Rh 2529 Coloque nuevamente el aireador en la salida Place the aerator in the faucet Cambio del Cartucho Cartridge Replacement Desenrosque la tuerca de sujeción cambie el cartucho y arme nuevamente Unscrew the retaining nut replace the cartridge and reassemble No se colocó el empaque The gasket is not placed Problema Problem Causas Causes Soluciones Solutions Existe poco flujo de agua There is...

Reviews: