Corner Canopy Hoods 

Model Number 13000

Installation, Operation, Maintenance Manual

                Phone (816) 796-2900

       Email info@HEMCOcorp.com

HEMCO Corporation
711 S. Powell Road
Independence MO, 64056

Visit www.HEMCOcorp.com

Call Toll Free: (800) 779-4362

Lab Planning Solutions

HEMCO

R

Summary of Contents for 13000

Page 1: ...ods UniFlow CE UniFlow LE FM Safety Equipment NSPE Scientific Equipment and Furniture Association SEFA ASME American Society of Mechanical Engineers National Fire Protection Association NFPA AEE Association of Energy Engineers Made In The U S A Corner Canopy Hoods Model Number 13000 Installation Operation Maintenance Manual Phone 816 796 2900 Email info HEMCOcorp com HEMCO Corporation 711 S Powell...

Page 2: ...nopy hood Generally air is being pulled from 3 to 4 sides CFM is based on the square foot area of the bottom of the canopy To ensure the proper exhaust flow the length of the ductwork and the number of 90 elbows needs to be known to calculate a total static pressure or resistance to size an exhaust fan 7 HEMCO Laboratory Planning Solutions www HEMCOcorp com info HEMCOcorp com Fax 816 796 3333 Tel ...

Page 3: ...etal framed stud walls it is recommended to align or move the mounting holes in the lower mounting bracket to be centered on wall studs for a more secure mounting Drill a pilot hole that is compatible with fastener type Lift the canopy and align to line from Figure 1 Attach Canopy to wall with fasteners 2 Installation of Exhaust and Electrical Connect Exhaust Ducting to top exhaust collar Per loca...

Page 4: ...sults should be recorded and reported to the proper authority for any required action Consult your company safety department for recommendations covering the materials you plan on using Cross drafts created by the room ventilation system or from an open window or corridor if located adjacent to the hood can drastically disturb the flow of air entering the fume hood face and even cause a reverse fl...

Reviews: