Installation, Operation, Maintenance Manual

Ductless Table Top Canopy Hoods

  Model  Numbers  24015,  24910                         

                Phone (816) 796-2900

                    Fax. (816) 796-3333

  Email info@HEMCOcorp.com

HEMCO Corporation

711 S. Powell Road

Independence MO, 64056

Visit www.HEMCOcorp.com

Call Toll Free: (800) 779-4362

Lab Planning Solutions

HEMCO

R

Summary of Contents for 24015

Page 1: ...ow CE UniFlow LE FM Safety Equipment NSPE Scientific Equipment and Furniture Association SEFA ASME American Society of Mechanical Engineers National Fire Protection Association NFPA AEE Association of Energy Engineers Made In The U S A Installation Operation Maintenance Manual Ductless Table Top Canopy Hoods Model Numbers 24015 24910 Phone 816 796 2900 Fax 816 796 3333 Email info HEMCOcorp com HEM...

Page 2: ... assembled wired and tested at the factory and is ready for set up and operation Please read through these instructions before beginning setup 1 Hood Location A Choose a work area away from heavy traffic and cross drafts As excessive air movement will ad versely affect the hoods ability to contain fumes B Place the hood on a level stable surface appropriate for use with your experiments 2 Operation P...

Page 3: ...ls understand your laboratory s action plan in case an emergency such as a power failure occurs Laboratory Safety for Chemical Fume Hoods 6 3 Filter Installation Filter Model 52004 2 individually wrapped filters in a 2 pack box Pivot the spring filter retainer latches to open position Remove filter from individual plastic wrapper Weigh new filter then record Lift filter in to position in the recessed a...

Page 4: ... Model 24015 is ideal for A Class 1 ductless hood workstation Activated Carbon Filtration for fumes odors non hazardous chemical vapors Perfect for areas where fume removal is essential fumes are vented through Cross drafts are reduced thus providing a turbulence free work area The light weight chemical resistant composite construction enables this unit to be easily transported from one location t...