5. Warnings and Recommendations

• WARNING - DO NOT use Table Top Canopy Hood(s) as a replacement where vented hoods are 
  required.  Used properly, the ductless fume hood will provide safe, effi  cient operation for limited 
  laboratory fumes and odors.

• RECOMMENDATION - Minimum fi lter change schedule of every 1-3 months or as required by 
  chemical properties and how they are used.

• RECOMMENDATION - Consult your Lab Safety Manager to assure the safe operation of this 
  ductless hood and fi lter.

Upon completion of the installation of your Table Top Canopy Hood it is a good idea to clean thoroughly 
to eliminate any miscellaneous debris and/or surface soil.

Any questions? Call HEMCO customer service at 1-816-796-2900.

4

HEMCO

Laboratory Planning Solutions

www.HEMCOcorp.com

   

   

 info@HEMCOcorp.com

      Fax (816) 796-3333

Tel (816) 796-2900

HEMCO Corporation

711 South Powell Road

Independence, MO 64056

R

5

 

1. Remove new fi lter from 

    plastic wrap, and write the 
    change date on the label.

2. Set fi lter in fi lter frame,  

     Note: arrows indicate 
       direction of airfl ow.

3. Snap the right and left 

  stainless steel fi lter clamps,
  to secure the fi lter in place.

Filter installation as easy as 1. 2. 3. ....

Model 24015 Ductless Table Top Hood

The Model 24015 is ideal for: A Class 1 ductless hood workstation. Activated Carbon Filtration for 
fumes, odors, non-hazardous chemical vapors. 

• Perfect for areas where fume removal is essential, fumes
  are vented through. Cross drafts are reduced, thus providing
  a turbulence free work area. 

• The light weight chemical resistant composite construction,
  enables this unit to be easily transported from one location 
  to another. 

• The units base work surface is factory installed and features
  a dished interior to contain spillage.

• Typical Applications include, Sample Weighing Stations,
  Histology, Student Work Stations, Handling Pharmaceuticals
  Micro Scope Stations, Hot Plate Venting, Micro press.

• Filter should be changed every 3-4 months depending 
  on volume of chemicals fi ltered.

Visit www.HEMCOcorp.com

Visit www.HEMCOcorp.com

Specifi cations:

Cat. No.

Ductless Table Top Hood

, 110V. with 6’ power cord, light switch, 

all fi berglass construction, 24” W X 24” H  X 15” D Compliant UL, 
CSA, and CE

24015

Ductless Table Top Hood

, 23V. with 6’ power cord, light switch, 

all fi berglass construction, 24” W X 24” H  X 15” D Compliant UL, 
CSA, and CE (International)

24025

Accessories:

Activated Carbon Filter  -

 Absorbs small 

amounts of non-hazardous fumes and odors.

52004

Clear Hinged Safety Shield -

 provides extra protection for user, 

size 6” X 6” X 11”

24121

24”

24”

15”

14.75”

Exhaust Fan Switch

Exhaust Fan Switch

Shown with optional Safety Shield

Summary of Contents for 24015

Page 1: ...ow CE UniFlow LE FM Safety Equipment NSPE Scientific Equipment and Furniture Association SEFA ASME American Society of Mechanical Engineers National Fire Protection Association NFPA AEE Association of Energy Engineers Made In The U S A Installation Operation Maintenance Manual Ductless Table Top Canopy Hoods Model Numbers 24015 24910 Phone 816 796 2900 Fax 816 796 3333 Email info HEMCOcorp com HEM...

Page 2: ... assembled wired and tested at the factory and is ready for set up and operation Please read through these instructions before beginning setup 1 Hood Location A Choose a work area away from heavy traffic and cross drafts As excessive air movement will ad versely affect the hoods ability to contain fumes B Place the hood on a level stable surface appropriate for use with your experiments 2 Operation P...

Page 3: ...ls understand your laboratory s action plan in case an emergency such as a power failure occurs Laboratory Safety for Chemical Fume Hoods 6 3 Filter Installation Filter Model 52004 2 individually wrapped filters in a 2 pack box Pivot the spring filter retainer latches to open position Remove filter from individual plastic wrapper Weigh new filter then record Lift filter in to position in the recessed a...

Page 4: ... Model 24015 is ideal for A Class 1 ductless hood workstation Activated Carbon Filtration for fumes odors non hazardous chemical vapors Perfect for areas where fume removal is essential fumes are vented through Cross drafts are reduced thus providing a turbulence free work area The light weight chemical resistant composite construction enables this unit to be easily transported from one location t...

Reviews: