WARRANTY

HEMOSTATIX MEDICAL TECHNOLOGIES, LLC (HMT) warrants to the original 

purchaser that reasonable care has been used in the manufacture of the MODEL P8400 

HEMOSTATIX THERMAL SCALPEL SYSTEM (HTSS) CONTROLLER and that, 

when properly used, it will be free from defects in material or workmanship for a period of 

one (1) year after the date of shipment from HMT or any of its authorized distributors.

NOTE

:  Hemostatix scalpel handles and blades are warranted to be free from defects 

in 

materials and workmanship for a period of SIXTY (60) days from the date of shipment 

The sole and exclusive remedy with respect to any MODEL P8400 HTSS or any portion 

thereof found within its warranty period not to meet these standards is that after return to 

and examination by HMT, HMT will without charge at its option either repair or replace 

that portion of the MODEL P8400 HTSS found to be defective. This warranty shall not 

apply (a) if that portion of the MODEL P8400 HTSS has been repaired or altered by 

anyone other than qualified service personnel approved by HMT or altered in any way 

which, in HMT’s judgment, affects its usability or reliability; or (b) if the sterile lot or serial 

number has been altered, effaced, or removed; (c) if the fault has been caused by abnormal 

conditions of operation or misuse including, but not limited to: dropping the controller 

unit; opening the controller unit; and/or permitting electrical contact with an active electro 

surgical (e.g., Bovie) electrode; operating the unit within 1 m of another electrosurgical 

controller unit; or, (d) if in the case of the scalpel blades or handles, the scalpel blades or 

handles have been reprocessed and reused. 

Except for the replacement of fuses, which can be accessed without opening the controller 

unit’s enclosure, any warranty, implied or expressed, is considered void if the tamper-proof 

seal on the controller unit’s enclosure is found to be broken. In all such cases, HMT’s 

determination will prevail and any repairs or replacements, if requested, will be billed at 

HMT’s prevailing normal rates. If so requested, estimates will be submitted before work is 

started.

NOTE

:  An RMA# issued by HMT must be obtained before any part of the MODEL 

P8400 HTSS is returned. 

NOTE

:  Handles and blades being returned must be cleaned, sterilized, and packaged in 

sterile packaging with labeling which verifies the sterility of the handle and/or blade prior 

to return to HMT. Any handle and/or blade not properly cleaned, sterilized and packaged 

as described in this warranty will be disposed of and no warranty will be in effect.

The foregoing express warranty, as conditioned and limited, is in lieu of and excludes all 

other warranties not expressly set forth herein whether expressed or implied by operation of 

law or otherwise including, but not limited to, any implied warranties or merchantability or 

fitness for particular purpose. HMT shall not be liable for any incidental or consequential 

loss, damage, expense or liability direct or indirect with respect to this product. HMT 

neither assumes nor authorizes any other person to assume for it any other or additional 

liability or responsibility in connection with this product.

SPECIFICATIONS

Model P8400 Hemostatix Thermal Scalpel Controller Unit

NOTE

: The MODEL P8400 HEMOSTATIX THERMAL SCALPEL SYTEM is 

suitable for continuous operation. 

Patient Leakage Current 

(From Patient Connection 

to Earth)

≤ 100 microamperes AC – Normal Condition

≤ 500 microamperes AC – Single Fault Condition

≤ 10 microamperes DC – Normal Condition

≤ 50 microamperes DC – Single Fault Condition

Blade Temperature Settings

• VARIABLE, set by USER and displayed

on front panel display as TEMPERATURE

SETTING ranging from 70° C to 300° C in

10° C increments.

Room Operating 

Environment

• 1

5

° C to 30° C (Note: Blade temperature is

indexed from room temprature

• 30% - 75% Relative Humidity - Non-

condensing

• 700 to 1060 hPA

Transport & Storage 

Environment

• -2

9

° C to +

5

0° C

• 10% - 

85

% Relative Humidity

570

 to 1060 hPA

Moisture Protection

• 7013-8400 Controller Unit  - 

IPX0

 Rating

• 7013-8410 Foot pedal  - IPX8

Console Size 

• Approximately 7.0 in x 10.9 in

Console Weight 

• Approximately 7.25 lbs. (3.3 kg) without power

cord

Power Requirements 

• 100-240VAC± 10%

• 50 - 60 Hz ± 1 Hz

Power Input

• 1 A

Power Output

• 60 W dc

Fuses 

• T 2A, H 250V (3AB Slo Blo, 2 Amp, glass

body, 6.35 x 31.75 mm) (Quantity 2)

Power Cord

• Approx. 10 ft. Hospital Grade

HEMOSTATIX 

THERMAL SCALPEL 

SYSTEM is classified as a 

Type BF Applied Part, Class 

I electrical device and is 

certified to the following: 

• IEC 60601-1 

Ed. 3.1 (2012)

• IEC 60601-1-

2 Ed. 4.0 (2014)

Summary of Contents for 7013-8400

Page 1: ...OPERATING MANUAL THERMAL SCALPEL SYSTEM MODEL PRECISION 8400 CONTROLLER Part Number 7013 8400 For use with the Model 9050 Disposable Scalpel Handles...

Page 2: ...pel blade must be uniformly maintained at the desired temperature within narrow limits The Hemostatix Thermal Scalpel System utilizes micro circuitry incorporated within the blade itself to maintain t...

Page 3: ...TSS before cleaning the unit to avoid electrical shock 5 To avoid the risk of electrical shock achieve electrical grounding reliability with proper connections Connect the HTSS unit to hospital grade...

Page 4: ...dal 25 GROUNDING Reliability can only be achieved when the equipment is connected to a properly equivalent receptacle marked Hospital Grade 26 STERILIZATION The Model P8400 Hemostatix Thermal Scalpel...

Page 5: ...into the handle as this would damage the blade s imprinted circuitry and render it inoperable 11 The handle must be energized for the COAG switch to work 12 DO NOT immerse the handle in liquid of ANY...

Page 6: ...s may become broken and the blade stop working 4 FOOTSWITCH An optional footswitch REF 7013 8410 is available which allows the surgeon to set the desired temperatures of the blades as well as activate...

Page 7: ...y packaged sterile and ready for use They are discarded when they become dull just like conventional cold steel scalpel blades Blades are single use only and should never be reused 2 Automatic Calibra...

Page 8: ...Thermal Scalpel Controller REF 7013 8400 is compatible with the following Hemostatix Thermal Scalpel handle cable configurations REF 7013 9050 Model P8400 Handle w Integral Cable Assembly Qty 1 REF 7...

Page 9: ...te the thermal COAG mode depress the blue Thermal COAG switch on the top of the handle The blade temperature will approximate 300 C in the thermal COAG mode NOTE The handle must be energized for the C...

Page 10: ...auxiliary output connector is to potentially offer other modules i e irrigation suction etc that would complement the existing Hemostatix technology WARNING The auxiliary port is not to be utilized fo...

Page 11: ...oagulate on the blade thermally insulating it 5 CHANGING THE BLADE If the blade becomes dull or the change blade message appears on the controller display switch the handle ON OFF switch to off and wa...

Page 12: ...E Before cleaning the controller detach the controller unit from the AC power source servicing The Model P8400 Hemostatix Thermal Scalpel System consists of the controller unit a handle and a blade If...

Page 13: ...tained before any part of the MODEL P8400 HTSS is returned NOTE Handles and blades being returned must be cleaned sterilized and packaged in sterile packaging with labeling which verifies the sterilit...

Page 14: ...statix Thermal Scalpel System Blades are available in the following configurations similar to cold stainless steel scalpel blades No 10 No 12 and No 15 blades Model P8400 Hemostatix Thermal Scalpel Sy...

Page 15: ...Manufacturer Manufacturing date Maximum DC Output Caution Authorized Representative in the European Community Temperature decrease Temperature increase Volume increase decrease Auxilliary output port...

Page 16: ...can affect the operation of the product GUIDANCE AND MANUFACTURER S DECLARATION ELECTROMAGNETIC EMISSIONS The Model P8400 Hemostatix Thermal Scalpel System is intended for use in the electromagnetic e...

Page 17: ...e user of the Model P8400 Hemostatix Thermal Scalpel System should assure that it is used in such an environment Immunity Test Test Level Compliance Level Electromagnetic Environmental Guidance Conduc...

Page 18: ...cording to frequency of transmitter m 150 kHz to 80 MHz outside ISM bands d 3 5 V1 P 80 kHz to 800 MHz in ISM bands d 3 5 E1 P 800 MHz to 2 5 GHz d 7 E1 P 0 01 d 3 5 3 0 01 d 3 5 3 0 01 d 7 3 0 01 0 1...

Page 19: ...TE 109 Bartlett TN 38133 USA Telephone 1 901 261 0012 Quality First International OU Laki 30 12915 Tallinn Estonia Hemostatix Medical Technologies LLC All rights reserved HEMOSTATIX is a U S A Registe...