Henden Salt and Mineral Chlorinator Owners Manual
HENDEN
INSTALLATION & OWNERS MANUAL
|
29
ALARM
ADD SALT
Figure 6.33
Once the HSMC registers a salt concentration within range (refer to recommended salt range section in the manual), the
HSMC will return to normal operation.
6.10 Low salt cut-out alarm
Should the salt concentration continue to be diluted, the HSMC will enter
LOW SALT CUT-OUT ALARM
.
ALARM
LOW SALT CUT-OUT
Figure 6.34
Once the salt concentration is corrected, the
LOW SALT CUT-OUT ALARM
must be reset by pushing the
manual
ON/OFF
button. Alternatively, the HSMC will conduct a system check automatically when powered up the next time (if
operating via a separate power supply). Upon start-up if the HSMC registers a salt concentration within range (refer to
recommended salt range section in the manual), the HSMC will return to normal operation.
LOW SALT CUT-OUT ALARM
is triggered at the following (approximate) salt concentrations:
HSMC model
Low salt cut-out alarm (approx. salt concentration)
HSMC15, HSMC25, HSMC30
2,500ppm
6.11 Add salt alarm and low flow alarm
Should the HSMC register low flow and a salt concentration below its minimum (refer to recommended salt range section in
the manual), the HSMC will alarm. The display will toggle between the
ADD SALT ALARM
and the
LOW FLOW ALARM
. In
LOW FLOW ALARM
, the HSMC will not produce chlorine. As shown previously once faults are rectified, normal operation
will resume.