6
EN
An example of recommended installation is shown
in Fig. A. Water outlet to drainage from the head
may be done by means of a 1/2” flexible garden
hose. An overflow elbow on the side of the housing
of the softener shall be connected to the drainage
in the same manner as the outlet from the head
(e.g., with a 1/2” flexible garden hose).
Connections to drainage shall be done below their
level in the water treatment system. Particularly
the emergency overflow of the softener housing
shall be observed – any potential excess of water
will be drained gravitationally.
After all connections are done, fill the salt tank
with 4kg of tablet salt. Salt shall be replenished
as the consumption thereof progresses, so that its
level is always above water level. Table 2 presents
average salt consumption per regeneration. Exclu-
sively tablet salt intended for water softening shall
be used.
Sample installation diagram of the water treatment system
Wa
ter sampler
Wa
ter sampler
Carbon filter
Per-filte
r
Sewage
100-240 VAC
Wa
ter softener
Treated wate
r
Wa
ter supp
ly
Gar
den
Diagram of the water treatment system
When installing and using the device:
• proper knowledge shall be possessed or profes-
sional services shall be commissioned
• it shall be ensured that the surface of installa-
tion is level and stable, as well as that the surface
will withstand the weight of the system filled with
water and salt tablets (in case of water softener)
• all connections shall be done in line with applica-
ble standards and provisions of law
• the device shall be connected to the existing wa-
ter installation with a flexible hose
• drainage to sewage shall be connected with a
flexible hose of the minimum hose diameter of
1/2”, of the length of the maximum of 6 m hori-
zontally
• solely and exclusively Teflon shall be used for
threaded seal-less connections
• the device shall be connected after all water in-
stallation connections are done
• perform resin regeneration after first connection
• periodically check water quality in order to en-
sure that the device operates properly
• use only the salt intended for water softeners,
of the purity of 99.5% minimum; use of fine salt
powder is prohibited
• the device shall be used in rooms of no excessive
air humidity and within the temperature range of
5 - 38°C
• use a reducing valve upstream the controller’s
water inlet if pressure exceeds 6.0 bar
• do not transport the device holding it by its hoses,
the injector, the by-pass or other sensitive ele-
ments of the controller
• use the accessories and parts delivered by a dis-
tributor only
• protect the device against the access of children,
since they can damage or deregulate the controller.