GAS REQUIREMENTS
Never use a gas cylinder with a damaged body, valve, collar, or foot ring. A dented or rusty gas tank may be hazardous
and should be checked out by a gas supplier.
Never connect this appliance to an unregulated gas source.
When the appliance is not in use, turn the gas cylinder OFF.
Always perform a leak test on gas connections whenever a cylinder is connected. If bubbles form in the leak test solution,
do not use. Never use a flame to test for leaks.
CONNECTING TO A GAS CYLINDER
Recommended to use 9 kg gas cylinder or refer to your gas supplier for suitable gas cylinder.
Approved gas regulator is used according to appliances categories and countries listed in data plate. Approved flexible
hose would be changed when the national conditions require it.
The length of hose to be used: 272800 & 272817: 0,45 + 0,8m; 272909 & 272916: 1.3m.
Assembly of the tubing must be conducted by some qualified tuber of destination countries.
The copper tubing of 272800 & 272817 must conform to related EN1057 standards of destination countries. The length of
copper tubing to be used for connection of 272800 & 272817 shall be at least 5m. The Diameter of the copper tubing is at
least 15mm. (272800 & 272817 only)
A safety device( Model No: TYP420A) must be used to connect copper tubing and regulator. The safety device is used to
shut of the gas supply in case of possible leakage of the gas piping system.(272800 & 272817 only)
The installation of 272800 & 272817 must be conducted by qualified personnel of destination countries. (272800 &
272817 only)
Only change gas cylinders outdoors or in a well ventilated area away from naked flames and any other source of ignition.
The gas cylinder must always be used in an upright position.
Close the heater control knob by turning fully clockwise.
Close the gas cylinder tap and then attach the regulator onto the gas cylinder.
Tighten all connections firmly and with a spanner where appropriate. The cylinder should be located on the cylinder base.
Check for leaks at all joints using soapy water. If a leak is found, tighten the joint and then re-test.
LEAK TEST POINT
connection between hose and copper tubing
connection between hose and safety device
connection between regulator and gas supply
Safety device, Model
No. TYP420A
Copper tubing conformed to
EN1507, tube Dia at least
15mm, tube length at least
5m.
Gas connecting of 272800 & 272817
Hose
0,45m
Hose
0,8m