Preventive Maintenance
12
17730-310
OPTIMAAX
®
Lift Axle System Air Controller Module for Freightliner
SECTION 8
Preventive Maintenance
AIR CONTROLLER MANIFOLD
Appropriate inspection procedure is important to ensure the OPTIMAAX system is accurately mea-
suring the system load .
■
On an annual basis –
the calibration of the pressure sensors, see Figure 8-1, in the air con-
troller manifold must be checked .
INSPECTION
1 . Connect the Diagnostic Tool Software .
2 . Apply shop air to the drive port with a calibrated pressure gauge .
3 . Displayed pressure in Diagnostic Tool Software must match pressure gauge measurement
within ± 5 PSI . If not, the air controller manifold must be replaced .
4 . Repeat Steps 2 and 3 for the lift port .
FIGURE 8-1
Hendrickson OPTIMAAX Diagnostic Tool
File
Log
Tools
Help
Displayed pressure
must match the
Pressure Gauge
measurement