Intelligence Aided Lifting Equipment
34
equipment will run at a "Slow Gear Upwards" speed, and when the contacts of Switch K1 are
disconnected, the equipment will stop. When the contacts of Switch K2 are connected, the
equipment will run at a "Slow Gear Downwards" speed, and when contacts of Switch K2 are
disconnected, the equipment will stop. When the contacts of Switch K3 are connected, the
equipment will run at a "Fast Gear Upwards" speed, and when contacts of Switch K4 are
disconnected, the equipment will stop. When the contacts of Switch K2 are connected, the
equipment will run at a "Fast Gear Downwards" speed, and when contacts of Switch K2 are
disconnected, the equipment will stop.
5.1.2 Fast gear and slow gear speed adjustment
The fast/slow gear speeds can be divided into 10 levels: the speed of each level is the level
number multiplied with 10% maximum speed. The user can set the fast/slow gear speeds through
the inching speed setting in the menu, by the following operations:
1. When the main interface displays “locking mode” (or “emergency stop mode”), click
“ENT” button to enter the main menu;
2. Select “lifting speed setting” with UP/DOWN, and click “ENT” button to enter its
menu;
3. Select “inching speed setting”
→
“fast gear setting” or “slow gear setting”, and select
the desired speed level with UP/DOWN, and click “ENT” button for confirmation; and
4. Press the “ESC” button to exit the main interface, and complete the setting of fast/slow
gear speed.
5.2 Switching of modes
When in a “locking mode”, the equipment can switch from the “locking mode” to the
“suspension mode”, or to “suspension unloading mode”, or to “unloading mode”. When the mode
is switched, select “open” in “suspension setting”
→
“suspension function switch”.
5.2.1 Usage mode
The control signal for the mode switching can be input by the host extension, handle
extension, or expansion board input port. Set the corresponding IO numbers in “Extended
Function Setting” → “Extended Port Setting” → “Switch Double Limit”.
For example
: take the 9
th
, 10
th
and 11
th
pins on the extension interfaces of the coaxial handle
as the inputs for the switching from the “locking mode” to the “suspension mode”, the switching
from the “locking mode” to the “suspension unloading mode”, and the switching from the
“locking mode” to the “unloading mode” respectively. Connect the 9
th
pin and the 6
th
pin on the