Intelligence Aided Lifting Equipment
61
equipment moves downward.
Password change
Set user password, with the initial password being
123456.
Multi-language
switch
Select the language on the user interface among Chinese,
English and French.
PLC switch
Turn on the PLC function.
(Submenu)
Hardware
diagnostic
Diagnosis of
handle board
extended port
Input and output signal test for the handle extended port,
for maintenance personnel.
Diagnosis of main
board extended
port
Input and output signal test for the main board extended
port, for maintenance personnel.
Diagnosis of
expansion board
extended port
Input and output signal test for the expansion board
extended port, for maintenance personnel.
Handle gripping
signal
When the infrared sensor detects an operator, the handle
gripping signal will change from “off” to “on”.
Fan diagnosis
Check whether the cooling fan of the main engine is in
normal state.
Upper limit signal
of hardware
When the equipment arrives at the upper limit of
hardware, the signal will change from “off” to “on”.
Lower limit signal
of hardware
When the equipment arrives at the lower limit of
hardware, the signal will change from “off” to “on”.
Signal of loose
steel wire rope
When any loose steel wire rope is tested by the system,
the signal will change from “off” to “on”.
Extended
function setting
Extended port
setting
Click to enter into extended port function setting.
Double suspension
setting
Click to enter into double suspension setting menu.
Anti-drop setting
Click to enter into anti-drop setting menu.
Homing setting
Click to enter into homing setting menu.
Switch of weight
interface
Turns the weight data transmission interface on/off.
Frequency of
weight interface
Set the frequency of the weight data transmission
interface.