Intelligence Aided Lifting Equipment
71
right only explains the
basic processing of
common
problems.
For details, see servo
driver
instruction
book.
The servo driver used
in the equipment is the
Delta ASDA-A2 series
high-performance
communication servo
driver.
battery. [Chapter 7.2.1]
Servo alarm AL061:
The voltage of the
encoder is too low.
Processing method: 1. Replace the servo driver
battery. [Chapter 7.2.1]
Servo alarm AL003:
Low voltage.
Processing method: 1. Check if the input
voltage is normal.
Servo alarm AL002:
Over voltage.
Processing method: 1. Check if the input
voltage is normal.
Servo alarm AL006/AL009:
Overload/position
error is too large.
Processing method: 1. Check if the servo power
cable connector is loose. 2. Check if the internal
steel wire rope servo of the host is stuck.
Servo alarm AL022:
The main loop power
supply is abnormal.
Processing method: 1. Check if there is a phase
loss in the input power supply.
Servo alarm AL000:
The alarm is not read.
Processing method: 1. For equipment with a
lifting capacity of 80KG or 200KG, please
restart the equipment to view the specific alarm
code. Open the front cover to view the real
alarm code. 2. For equipment with a lifting
capacity of 300KG, 600KG, if the equipment
still displays the AL000 alarm after restart, then
check whether there is a phase loss in the input
power supply. Open the front cover to view the
real alarm code.
Servo alarm AL06A:
The absolute value has
not been initialized, and this alarm may appear
after the replacement of battery or motor.
Initialization steps: