Intelligence Aided Lifting Equipment
36
5.4 Double suspension function
The double suspension function allows the equipment to remain in the suspension mode at all
times, and realizes the suspension load switching between the fixture weight and f work
piece weight, and is particularly suitable for the positional installation of the work piece in the
suspended state. The switching operation between the double suspension functions shall set the IO
signal of the extended function, and shall access the switch or sensor according to different
working modes.
The implementation of the double suspension function requires that the system presets the
load weights in two kinds of suspended states, and then set different extended IO signals
according to the selected double suspension mode.
Note:
Regardless of the mode in which double suspension works, the equipment load must
meet the following conditions:
If |Load weight - (any) pre-set the weight value| <= (operating
force - 0.5), it can normally start and enter into the double suspended state!
Double suspension is divided into fixture suspension and fixture work piece suspension.
5.4.1
Double suspension weight setting
①
Perform submenus for “Extended Function Setting”
→
“Double Suspension Setting”;
②
From the double suspension setup menu, enter the “fixture weight” submenu. When the
equipment hangs the fixture and remains stable, click “ENT” button to record the weight
of the fixture (the maximum fixture weight can be set to 60KG);
③
Same as the previous step, in the “fixture work piece weight”, the jig work piece is
suspended and remains stable, and the “fixture work piece weight” is recorded; click
“ESC” button to return to the previous menu.
5.4.2
Double suspension mode setting
The double suspension function enters the double suspended state mode according to the
entering equipment, and is divided into two types: automatic and manual.
Enter “extended function setting”
→
“double suspension setting”
→
“double suspension
mode” submenu in the handle to complete the selection of double suspension mode.
In the automatic mode, the detection time must be set first. When the load weight of the
equipment (fixture or fixture work piece) is in the weight range required to enter the double
suspension mode, and when the accumulated time reaches the set detection time, then the
equipment automatically enters the double suspension mode.
In the manual mode, the equipment must be manually operated to enter the double suspension
mode. According to the set signal selection, the user shall hold the button signal for about 2