background image

 N-NKS-11-D-e-08-1/1 

 

Hengesbach GmbH & Co. KG  

·

  Schimmelbuschstr. 17 

·

  D-40699 Erkrath  

· 

 Tel. +49 (0) 21 04 / 30 32-0  

·

  Fax +49 (0) 21 04 / 30 32-22   

· 

www.hengesbach.biz

 

Conductive level sensor  

- Type NKS 11 - 

 

 
     

 

 
 

              

 

 

 

 

 

DESCRIPTION

  

  

 
The conductive level sensors are mainly used to detect conductive threshold levels in liquids such as fruit juices, beer, 
milk, etc. with a minimum conductivity of 5 µS.  
 
The favourable design, with its sealing cone and the corresponding welding sockets, means that there are no places in 
which residues can collect. The sensor is therefore easy to clean and suitable for use in the food and pharmaceutical 
industry, etc. CIP- and SIP-suitability are guaranteed. 
 
The non-corrosive materials used for the rod and insulation mean that the sensor is also suitable for corrosive media. 
Various process connection forms render optimal adaptation to the application possible. The sensor can be shortened, 
which has a positive and practical effect on storage. The electrode is coated with HALAR, which means that the 
threshold level detection is also suitable for foaming media. 
 

TECHNICAL DATA 

 

 

 

            ACCESSORIES  

 

Electrical connection 

cable gland M16x1.5  

 

     - Please quote separately when ordering -  

 

 
bipolar terminal (2.5 mm²)  

 

- welding socket with sealing cone (zem / TP 16),  
  Item No. 06002001 

 optional: 

 

M12x1 connection plug 

 

- spherical welding socket with sealing cone  
  (zem / TP 35),   Item No. 06002298 

Type of protection 

IP 67 acc. EN 60529 

 

- screw connection can also be combined with other 
  installation systems  

Process connection 

standard NKS 11: 
G ½ B threaded connection, 
1.4571 / metal seal, 
torque: approx. 15 Nm 
optional NKS 13: 
G ¾ B with union nut and O-
ring for welding socket  
G ¾, l= 1500 mm, d= 11 mm 

 

 
 
 
 
 

 
INSTALLATION INSTRUCTIONS 

Electrode length 

200, 500, 800, 1500 mm, can 
be shortened, other lengths on 
request  

- the maximum permissible torque (15 Nm) must be 
  taken into account when fitting the sensor 

Operating temperature 

max. 140 ºC 

 

- the tank or pipe wall must be made of metal 

Environmental 
temperature 

-10...+60 ºC 

 

- when installing the sensor, only use the 
  key surface, not the connection head   

Operating pressure 

Pmax = 6 bar 

 

- the process connection thread of the sensor must  
  have free electrical contact to the wall of the pipe/tank 
  (do not use any insulating   sealing materials !) 

Insulation 

PEEK  (FDA-approved) 

 

 

Sensor rod 

stainless steel 1.4571, ø 4 mm 

 

 

Coating 

ECTFE (HALAR), ø 0.7 mm, 
FDA approved 

 

 

 

 

CONDUCTIVE THRESHOLD LEVEL DETECTION  
OF LIQUID MEDIA 

 

 

VERSION SUITABLE FOR HIGH-HYGIENE 
ENVIRONMENTS EHEDG / FDA 

 

 

STAINLESS STEEL HOUSING IP67 

 

MAINTENANCE-FREE 

 

OPTION:  WITH NM LEVEL MODULE 

 