DESCRIPTION
The conductive level sensors are mainly used to detect conductive threshold levels in liquids such as fruit juices, beer,
milk, etc. with a minimum conductivity of 5 µS.
The favourable design, with its sealing cone and the corresponding welding sockets, means that there are no places in
which residues can collect. The sensor is therefore easy to clean and suitable for use in the food and pharmaceutical
industry, etc. CIP- and SIP-suitability are guaranteed.
The non-corrosive materials used for the rod and insulation mean that the sensor is also suitable for corrosive media.
Various process connection forms render optimal adaptation to the application possible. The sensor can be shortened,
which has a positive and practical effect on storage. The electrode is coated with HALAR, which means that the
threshold level detection is also suitable for foaming media.
TECHNICAL DATA
ACCESSORIES
Electrical connection
cable gland M16x1.5
- Please quote separately when ordering -
bipolar terminal (2.5 mm²)
- welding socket with sealing cone (zem / TP 16),
Item No. 06002001
optional:
M12x1 connection plug
- spherical welding socket with sealing cone
(zem / TP 35), Item No. 06002298
Type of protection
IP 67 acc. EN 60529
- screw connection can also be combined with other
installation systems
Process connection
standard NKS 11:
G ½ B threaded connection,
1.4571 / metal seal,
torque: approx. 15 Nm
optional NKS 13:
G ¾ B with union nut and O-
ring for welding socket
G ¾, l= 1500 mm, d= 11 mm
INSTALLATION INSTRUCTIONS
Electrode length
200, 500, 800, 1500 mm, can
be shortened, other lengths on
request
- the maximum permissible torque (15 Nm) must be
taken into account when fitting the sensor
Operating temperature
max. 140 ºC
- the tank or pipe wall must be made of metal
Environmental
temperature
-10...+60 ºC
- when installing the sensor, only use the
key surface, not the connection head
Operating pressure
Pmax = 6 bar
- the process connection thread of the sensor must
have free electrical contact to the wall of the pipe/tank
(do not use any insulating sealing materials !)
Insulation
PEEK (FDA-approved)
Sensor rod
stainless steel 1.4571, ø 4 mm
Coating
ECTFE (HALAR), ø 0.7 mm,
FDA approved
CONDUCTIVE THRESHOLD LEVEL DETECTION
OF LIQUID MEDIA
VERSION SUITABLE FOR HIGH-HYGIENE
ENVIRONMENTS EHEDG / FDA
STAINLESS STEEL HOUSING IP67
MAINTENANCE-FREE
OPTION: WITH NM LEVEL MODULE