116
4 Programming the presets, correction values and prescaler
4.3 Setting the signal times
If with the function codes F7 and/or F8 an output signal is set to monostabil, the following programming sets the
signal time. You get to the programming mode by pressing the buttons E + UP while switching on the counter.
In the programming mode, the digit that you want to change is selected by the SHIFT-button. This digit is
blinking. With each pressing of the SHIFT-button, the selected digit is going one position to the left. With the
UP-button the value of the selected digit is raised by one.
The maximum settable time is 599,99 s.
By pressing the E-button the counter switches to the setting of the next signal time. Pressing the E-button again
saves the set values and returns to the display mode. For counters with one relay, only one signal time is possible
to set.
Pressing UP- and R-button at the same time, the value is set to zero.