8 of 12
Instruction handbook
Version 1.0 · 23.12.17
EN
6) PREPARING THE DISPENSER
FOR USE
Instruction and reporting obligation
The operator ensures that all activities at the dispenser are
only carried out by authorized persons. He provides thor-
ough instruction for all persons working on the device, with
special emphasis on the residual dangers and safety regu-
lations, based on this instruction handbook.
The operator is obliged to report all defects occurring
during operation to the manufacturer if the instruction
handbook does not contain any information on how to
remedy these. Measures specified by the manufacturer
must be strictly complied with.
Notices
CAUTION
Risk of crushing by
extending plunger!
Only connect the dispenser to the com-
pressed air network after the cartridge has been
inserted correctly, see " Inserting the cartridge" on
page 9.
Never put your hands or fingers between the pneu-
matic plunger and the cartridge.
CAUTION
Risk of injury and
poisoning by hazardous substances!
Always observe the safety regulations of
the manufacturer for the 2-component materials (refer
to the safety data sheets).
CAUTION
Risk of injury in the event
of incorrect use of the cartridges /
plunger discs!
Refer to figure
{E}
on page II:
Always mount the right upper plunger disc (26)
(B-side).
Never use cartridges that are inappropriate for the
plunger.
Never replace the lower plunger disc (27) (A-side),
it remains firmly fixed in place.
Check the correct fixture of the plunger discs peri-
odically.
Procedure
Refer to figures
{A}
,
{E}
,
{F}
,
{G}
on page II:
1.
Select an appropriate plunger disc (26) and fix in
place with socket head screws. Always use the
largest possible plunger disc.
2.
Remove the protective cap from the compressed air
connection (20), connect the compressed air hose.
Never fit the compressed air hose on the protection
cap!
3.
Install the correct adapter (1/4”) with internal thread
onto the compressed air connection (20) (not
included in the scope of delivery).
WARNING Risk of tripping over the
compressed air hose / due to lack of
cleanliness at the workplace!
Always ensure that the workplace is clean and tidy.
Lay compressed air hoses so that they do not cre-
ate a tripping hazard for the operator or bystanders.
4.
Fix the atomizing air hose (6) on the plug connection
(7).
5.
Adjust the handle (16):
a) Release the handle (16) (a)
b) Swivel the handle into the required position (b).
c) Fix the handle (c)
For cartridges with mixing ratios 1:1, 2:1, 3:1
and 4:1, the plunger discs (5) shown in figure
{A}
are already included in delivery.