9 of 12
Instruction handbook
Version 1.0 · 23.12.17
EN
7) OPERATION
Inserting the cartridge
WARNING Risk of injury if the wrong
cartridges are used or used incorrectly!
Only use Henkel cartridges, otherwise
damage claims are forfeited.
Observe the safety instructions on the cartridge
Always place the cartridges with the largest vol-
umes at the bottom (A-side) when cartridges have dif-
ferent volumes.
Use Henkel spraying head (31), air hose (6) and
connector (30)
CAUTION
Risk of crushing by extend-
ing plunger!
Never insert the cartridge when the dis-
penser is connected to the compressed air supply.
Refer to figure
{H}
on page III:
1.
Insert the cartridge into the cartridge holder and
press downwards until it locks into the cartridge
holding clips (17). The cartridge detection feature
enables use of the device.
Connect the dispenser to the compressed
air supply
Refer to figure
{I}
on page III:
NOTICE
Risk of damage due to incorrect
compressed air supply!
Observe the requirements for the compressed air sup-
ply. Refer to Chapter "10) Technical data" on page 11.
Connection of an upstream compressed air main-
tenance unit is recommended
1.
Connect the compressed air hose to the
compressed air connection (20) via the quick-
release coupling.
Equalizing the cartridge materials
Refer to figures
{I}
and
{J}
on page III:
1.
Unscrew the cap nut (29).
2.
Remove the cartridge stopper (28).
3.
Connect the atomizing air regulator (24)
4.
Set the pressure regulation valve (22) to the
minimum discharge quantity.
5.
Press the trigger (21) until both components are
evenly pressed out of the cartridge. The trigger can
not be actuated if the cartridge has not been
inserted correctly.
Fix the mixer onto the cartridge
Refer to figure
{K}
on page III:
1.
Remove any blockages in the cartridge and the
cartridge sleeve with a clean cloth.
2.
Fix the mixer (25) with a cap nut (29) on the
cartridge outlet thread.
3.
Press the quick connector of the atomizing air line
(30) onto the spraying head (31) until it locks into
place.
Dispensing the materials
Refer to figure
{L}
on page III:
1.
Press the trigger (21) up to its first stage (I). Atom-
izing air is transported through the atomizing air
hose (6) to the spraying head (31).
2.
Press the trigger (21) up to its second stage (II).
Materials are pressed out of the cartridge and
combined in the mixer (25), the compound is atom-
ized with the atomizing air when it is discharged
from the spraying head (31).
3.
Adjust the volume of atomizing air with adjustment
wheel (24) and the volume output with adjustment
wheel (22).
WARNING Risk of serious injury
caused by discharge of high pressures
and/or bursting of the dispenser!
Before operation, always replace the upper
plunger disc with one suitable for the
cartridge used, see "6) Preparing the