background image

Installation & Programming Manual

Page 25

to regenerate and/or delete a

portion of the previously

found data

It is possible to select data using the left-hand mouse button and dragging the dotted lines

which appear over the area of interest. At the end of the selection, press the “Redraw” button.

to search for data in the

newly selected time interval

Summary of Contents for Lineguard AT05

Page 1: ...Manual Lineguard AT05 ...

Page 2: ...4 2 1 Home Menu 8 3 Setup Session 9 3 1 Login Access 9 3 2 Generic Setup 10 3 3 Control Device 12 3 4 Port Configuration 13 3 5 Recipe Editor 13 3 6 Measure Calibration 16 4 Service 18 4 1 System 18 4 2 Serial Com 21 4 3 Info and Miscellaneous 22 5 Data Session 23 5 1 Data View 23 5 2 Graph View 24 6 Registers 26 ...

Page 3: ...s made up of software which operates using the Microsoft Windows operating system This feature makes it extremely versatile because it puts the whole series of characteristics implicit to Windows at the operator s disposal for example the quick and easy import export and exchange of data be it in text or graphic form between the various applications After an initial phase of selecting and setting ...

Page 4: ...and the relative parameters and is the AT 05 system s main panel It holds many functions which can be accessed via the various ICONS Recipe Default displays the name of the recipe in production displays appliance status in real time displays the last error which occurred on the line Manifold level indicator icon GY OFF GN ON product presence displays the variables depending on the analysis configu...

Page 5: ...intenance icon tank levels indicator icon yellow pre alarm reagent almost finished Red Alarm reagent finished it is not possible to continue with titration click on the icon to call up a panel indicating which reagent has triggered the pre alarm error or how many measurements have already been carried out with the level not present icons of the lines present from which the user can access the conf...

Page 6: ... last analysis performed The system can manage a maximum of 6 lines Start if the configuration is in remote mode this allows the user to start analysis on the selected line If the configuration is in automatic mode it allows the user to start the analysis only if the wait time on the line is 0 Itis possible to book the analyses to be carried out in sequence but only in the remote configuration Err...

Page 7: ...nels certain common icons are available to exit the panel without saving changes move onto the next data setting on the same page Save personalizations or set data start the appliance by enabling the starts on the analysis lines stop the analysis or calibration cycles exit the panel access the calibration measurement panel create a file containing the measurement parameters to be sent to the Masel...

Page 8: ...the software and change the access login to access the general settings session to exit the software and turn off the appliance to exit the software to access the calibration alarms events registers to access the production data management panels to see the instruction manual in pdf format to access the main display panel to access the service panels to access the management and email register pan...

Page 9: ...e data of 10 users is displayed at a time press the Next button to move onto the following 10 users To implement user management enable this function by selecting the Yes option in the box illustrated below If No is selected in this function no login and password will be requested when the program is launched Another general option which concerns management of the users is the possibility to have ...

Page 10: ...be different for each user If two or more password entered are the same the problem will be indicated so that the passwords changes can be made c Level the selection of the level involves allowing or denying access to certain functions LEVEL 0 allows the user to see the current measurement values the measurements archive and start stop the analysis LEVEL 1 as well as the previous functions the use...

Page 11: ...sor set this function to Disabled Serial Number enter the Serial Number of the appliance which will be used when the configuration backup is created Operation FUNCTION NOT ACTIVATED Temper Unit FUNCTION NOT ACTIVATED Minimizable set Yes if you wish to reduce the main panel to an icon function only active for Level 3 users Remote Silence AT 05 Panel can manage audible alarm signals with this option...

Page 12: ...n set for all parameters modified in the recipe confirmation to save will be requested If the function is set to Aut modifications will be saved automatically The Auto with conf function will request confirmation only once if all the modifications to the recipe are to be saved Virtual keyboard for activating deactivating the virtual keyboard Virtual keyboard type for selecting the type of virtual ...

Page 13: ...setting 3 5 Recipe Editor for production recipe management On the left hand side you will find the Product Operations box which holds the main operations which can be performed Capture from line Send to Line New Product Save on Disk Recall from Disk Delete Product Once the selection has been made the Product Manager panel takes on a new aspect displaying fields which were not previously visible ...

Page 14: ...eived from a certain line or create a new recipe enter the data by which the system will subsequently identify the product If the name and number have already been selected they can be used to save the newly received parameters The functions in this box are specific according to the line selected the main functions are described in the headings following this chapter ...

Page 15: ...tion parameters These may vary depending on the hardware and software configuration of the analysis equipment 3 5 2 New Product By selecting New Product the user can create a new recipe starting from the default values stored in AT 05 Panel if necessary Use the Parameters field located on the right hand side of the panel to consult and modify if necessary the default values 3 5 3 Save On Disk Save...

Page 16: ...ram in 2 ways 1 in alphabetical order according to the name of the product 2 in numerical order according to the identification number of the product in this case there are a series of buttons to facilitate selection of the product number which can be reached in groups each containing 100 products 3 6 Measure Calibration to activate the continuous calibration measurement procedure of the measured ...

Page 17: ...t calibration activation of the bowl or stirrer drain and washing commands start of a new calibration depending on the results of the calibration specific messages and updates of the relative parameters will appear click on the Advanced button to call up a panel for accessing the settings of the measurement and calibration parameters of the variables ...

Page 18: ...pdate the instrument and perform backup operations N B THE SUBMENU ICONS CHANGE COLOR DEPENDING ON THEIR STATUS 4 1 System to access the diagnostics menu The various icons allow the user to activate the valves on the manifold or check the levels in the manifold or the air pressure sensor ...

Page 19: ...des analog values activation of the dilution system activation of the extravolume system activation of the washing system activation of the discharge system activation of the stirrer to activate the product reagent delivery pumps to check the level in the tanks ...

Page 20: ...ramming Manual Page 20 to check the status of the external start inputs to activate the alarm relays to activate the appliance ready output to check the stop titration input to manage the dispenser valves and movements ...

Page 21: ...erial communication with the dispenser 4 2 Serial Com to check the serial communication with the internal CPU Displays the software version MR04 Function reserved for the assistance Deletes the appliance s operating parameters WARNING only perform this operation when directed to do so by the Assistance Service ...

Page 22: ...to save in txt format all the machine operating parameters or make a backup of them to update the various appliance softwares PC Panel and MR04 to restore in the appliance s electronic section MR04 all the data saved during the last backup operation to execute complete washing of the analysis cells and sampler The function is available only when the machine is not carrying out any analysis ...

Page 23: ...Session to consult and export the date in graphical and numerical reports 5 1 Data View to display the report in a numerical format It is possible to filter the data relative to a single measurement To activate filtering enable the Filtering option ...

Page 24: ...llation Programming Manual Page 24 to select the time interval during which you wish to analyze the data to select which parameters to be displayed 5 2 Graph View to display the report in a numerical format ...

Page 25: ...rtion of the previously found data It is possible to select data using the left hand mouse button and dragging the dotted lines which appear over the area of interest At the end of the selection press the Redraw button to search for data in the newly selected time interval ...

Page 26: ...Installation Programming Manual Page 26 6 Registers to check when and how the various calibration procedures were performed the alarms and events register and the list of operations executed ...

Page 27: ...Installation Programming Manual Page 27 ...

Reviews: