6
5
Operation: Teroson® Telescopic Multi-Press Dispenser
Instruction for Use:
For the application of Terostat-9320 Sprayable Seam Sealant and other 300 ml cartridges.
How to apply Terostat-9320 SF
1)
Open cartridge
Puncture aluminum base of cartridge with
enclosed tool. Use point to pierce membrane
at tip of nozzle.
2)
Prepare cartridge
Screw material nozzle hand-tight onto
cartridge.
3)
Insert cartridge
Slide cartridge into chamber of spray pistol.
Screw blue nozzle cap tightly onto tube.
4)
Screw on air nozzle
Screw air nozzle onto blue nozzle cap.
Regulating air pressure
The multi-press pistol has a dual-circuit air
system! Mains pressure should be at least 7
bar (100 p.s.i.) Higher air pressure is reduced
automatically.
5)
Adjusting knobs
Flow of material and flow of air can be
adjusted independently of one another by
means of the adjusting knobs.
Red adjusting knob = flow of material
Blue adjusting knob= flow of air
6)
Spray functions
Adjust knobs to produce required spray
pattern.
7)
Sealing seams
Spray from a distance of 4 cm, with nozzle
held vertically and at right angles to seam
8)
Coating surfaces
Spray from a distance of 20 cm, with nozzle
held vertically and at right angles to seam.
9)
Fine spraying
For spraying surfaces with a fine coating, the
material flow must be reduced.
Red adjusting knob: screw in towards (-).
10)
Applying a bead without spraying
If a bead is to be applied, the air (blue
adjusting knob) must be totally switched off
and the black nozzle cap in position.
11)
Reducing the flow of material
The flow of material can be reduced by
means of red adjusting knob.
Red adjusting knob: Turn in towards (-).
Important
When the pistol is not spraying, the full
pressure is taken by the red adjusting knob.
The red knob must therefore be closed more
firmly.
Summary of Contents for Teroson 142241