5 Installation
Consult Technical Data on page 38 for the specifications of the machine.
Before installing the machine, carefully read the safety instructions in Safety on page 9.
Failure to follow or disregard of the safety instructions may result in serious injury.
5.1 Transportation and Installation
The machine must be moved and transported in an upright position.
1.
Place the machine on a flat, level surface. This is essential to ensure a trouble-free operation
of the machine.
Do not position machines with plastic covers in the vicinity of a heat source.
Make sure there is sufficient space (at least 15 cm) around the machine to ensure a
proper ventilation.
2.
Verify that the machine housing is present and correctly fitted.
5.2 Connecting the Machine
Only a technical expert may perform work on the electrical installation.
Make sure the power supply for this machine matches to the voltage and amperage stated on the
machine plate.
Specified amperage: 16 /fuse
20 C
Description
16
Nominal amperage
Fuse 20
Minimum fuse value with the recommended type of fuse
C
C characteristic
1.
Fit the connecting cable to the machine. See Technical Data on page 38 for the correct
electrical connection.
2.
Connect the machine to a grounded wall outlet to avoid fire or electric shock.
Installation 17