Malfunction
Activity
More information
Vacuum bag is not sealed cor-
rectly.
•
Check the seal settings of
the programme and adjust
them.
•
Check/replace the Teflon
tape and the sealing wires.
•
Check/replace the silicone
rubber of the silicone hold-
ers.
•
Check the inside of the va-
cuum for contamination and
clean it.
Operation on page 19.
Replacing the Sealing Wire on
page 25.
Replacing the Silicone Rubber
of the Silicone Holders on page
27.
The lid does not open automat-
ically.
•
Check the gas spring/
springs of the lid.
Contact your supplier.
Error messages for the 1-PCS
Malfunction
Activity
More information
"F1" in display.
•
Check or adjust the switch
of the lid.
•
Verify that the vacuum pump
is running.
Contact your supplier.
"F2" in display.
•
Check whether the lid is
open.
•
Restart the machine.
In case the malfunction reoc-
curs, contact your supplier.
--- in display.
•
Check whether the lid is
open.
Flashing "C" in display.
•
This is a reminder to run the
pump cleaning programme.
•
Run the pump cleaning pro-
gramme.
Oil Notification (if activated).
A service check is needed.
Contact your supplier.
Troubleshooting and Error Codes 35