background image

 
 
 

Seal bar 

10 

User manual Compact Eco-range 

 
 
 

 

 

4  SEAL BAR 

 

 

Clean the sealing and counter bars daily to ensure optimum sealing of the packaging material. Use 
a dry cloth for this purpose. 

 

Check the condition of the sealing wires regularly. They should be free of kinks and should be 
tightly strung on the sealing bar. For flawless operation the Teflon tape must be free of damage. 

 

If the sealing wires or the Teflon tape are damaged, replace them immediately.  

 

Check the counter bar. This is made of silicone which generally has a long operational life and 
therefore does not need replacing often. However, if parts of the beam are scorched, replace the 
silicone strip immediately.  

 

Ensure that spare sealing wires and Teflon tape are always kept in stock.  

 

4.1  Replacing the seal wire and teflon tape  

Removing of old materials  

1.  Remove the seal bars by pulling these up. 
2.  Remove the old teflon tape (5). 
3.  Unscrew the hexagon socket screws (4) 
4.  Check if the tightening springs (2 & 3) at the end of the bars are present. The tightening springs are 

necessary to catch up the expansion of the wires during the heating process.   

5.  Remove the seal wire (6) 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

POS 

Description 

Beam 

Spring 

Screw 

Hexagon socket screw 

Teflon tape 

Seal wire 

 
 

 

Fig. 4-1 

Summary of Contents for COMPACT ECO Series

Page 1: ...l info henkovac nl User manual COMPACT ECO RANGE Manufactured by Het Sterrenbeeld 36 5215 ML s Hertogenbosch The Netherlands P O Box 2261 5202 CG s Hertogenbosch The Netherlands tel 31 0 73 6271271 fa...

Page 2: ...known at the moment of publication so that we reserve the right to make changes without giving prior notice This document is applicable to the indicated models of the Henkovac packing machine in the...

Page 3: ...8 3 2 Clean Daily 8 3 3 Weekly maintenance 8 3 4 Monthly maintenance 8 3 5 Annual maintenance 8 3 6 Oil 9 4 SEAL BAR 10 4 1 Replacing the sealing wire and Teflon tape 10 4 2 Replacing the sealing wire...

Page 4: ...t all times for observing the locally applicable safety regulations and guidelines Obey all safety instructions and guidelines as given in this manual Users manual Every user should be informed of the...

Page 5: ...untry Check the oil level The temperature in the workspace should not be lower than 10 C or 50 F as the oil in the vacuum pump will thicken and prevent the smooth operation of the pump Always remove t...

Page 6: ...chamber B Buttons to adjust Vacuum time Press to increase the vacuum time Maximum 99 sec Press to decrease the vacuum time Minimum 0 sec Adjustable per 1 second C Buttons to adjust Seal time Press to...

Page 7: ...etween 0 and 99 seconds and adjustable per 1 second Only when vacuuming the attained vacuum can be seen on the vacuum gauge A It is important that the vacuum time for products with enclosed air is ext...

Page 8: ...ent as this weakens the acrylic material Warming up vacuum pump In order to prevent oxidation in the pump the vacuum pump must run for about 5 minutes after cleaning to allow the condensed water in th...

Page 9: ...ph 2 1 2 Switch the pump of and remove the power cable from the socket 3 Use a tray for catching the oil 4 Remove CAP A 5 Loosening the oil filler plug B 6 Loosening the oil drain plug D 7 Make sure t...

Page 10: ...y has a long operational life and therefore does not need replacing often However if parts of the beam are scorched replace the silicone strip immediately Ensure that spare sealing wires and Teflon ta...

Page 11: ...backing strip and stick the tape onto the bar 4 4 Replacing the silicone in the counter bar Replacement of the rubber is done as follows 1 Pull the rubber out of the counter beam 2 Clean the groove 3...

Page 12: ...machine Length mm 550 550 670 670 Width mm 470 470 670 710 Depth mm 670 670 660 660 Weight Kg 36 46 65 80 Size of the vacuum chamber Length mm 365 365 385 420 Width mm 280 280 360 460 Depth mm 95 95...

Page 13: ...0 C Transportation temperature 25 to 55 C Humidity 30 to 95 without condensation Positioning Inside level free of walls etc Voltage data was not included in this summary because these are dependent on...

Page 14: ...um function is too low Increase the value of the vacuum function There is not enough oil in the pump Replenish the oil The oil is dirty Change the oil The suction filter is blocked Contact your author...

Page 15: ...his declaration refers comply with the following standards EN 60204 1 1997 EN 60335 1 1994 EN 55014 EN 60555 2 and EN 60555 3 EN 55014 2 carried out using the values of the EN 50082 2 according to the...

Reviews: