10 • Service Manual — COATS Models 950/950 ProRacer/1025/1050/1055
Direct Drive
Is the hub nut broken or
the cones damaged?
Is the balancer sitting on
a hard flat surface.?
Is the balancer located near a
piece of equipment that
causes the floor to vibrate?
Replace the damaged
part(s).
Move balancer to a another
location in the shop.
Mark the wheel & faceplate with
a piece of chalk and check after
each spin. Is the wheel slipping
against the face plate?
Clean the faceplate and/or remove all
nicks. Make sure wheel is chucked
tightly against faceplate
No
Check the piezo wiring at the
piezo and at the P.C.B. plug for
good connections.
Repair defective
connection(s).
Good
Yes
Replace the drive motor
assembly. See
Replacement Procedure
No
Replace the PCB. See
Replacement Procedure. Did this
correct the problem?
Adjust springs. See step, 19 in
“DRIVE MOTOR REPLACEMENT
PROCEDURE”.
Did this correct the problem?
Yes
Check/replace piezos, see the
procedure on page 32. Did
this correct the problem?
No
Yes
Yes
No
Yes
Yes
No
Bad
No
No
Check/replace the optical
encoder. See the procedure on
page 30 - 31. Did this correct
the problem?
Yes
No
Return to FUNCTIONAL
CHECKS.
Check the tension adjustment on the
motor springs. See step 19 in the
"DRIVE MOTOR REPLACEMENT
PROCEDURE".
Where they adjusted properly?
No
Yes
Repeatability Problems (Contactor & Motor Controller Model)