Service Manual — COATS Models 950/950 ProRacer/1025/1050/1055 • 13
CONTINUED FROM
LAST PAGE
Is there 230VAC from terminals
64 to 74, 74 to 84,& 84 to 64 on
the forward contactor?
Repair or replace defective
jumper wire or connections.
*Manually close the forward contac-
tor & check for 230VAC on terminals
63 to 73, 73 to 83, & 83 to 63 of the
forward contactor.
Manually close the forward
contactor. Use an Ohmmeter to
check from terminal 2 to terminal 1
on the forward contactor.
Use an Ohmmeter to check from
terminal 74 on the brake contactor to
terminal 2 on the forward contactor.
Yes
No
Voltage Present
Less Than 1 Ohm
Less Than 1 Ohm
Replace the contactor.
See Replace Proce-
dure.
Less Than 1 Ohm
More Than
1 Ohm
More Than
1 Ohm
More Than
1 Ohm
Voltage
Not
Present
Replace the forward
auxiliary contactor. See
Replace Procedure.
Repair or replace
defective jumper wire
or connections.
Turn the power switch OFF & unplug
the machine. Use an Ohmmeter to
check from terminal 53 on the
forward contactor to terminal 74 on
the brake contactor.
Is this a Model 1050.
No
Yes
If this is a single phase unit try
repalcing the capicator assy.,
See Replace Procedure.
After verifying the integrity of
the motor connections at the
contactor. Replace defective
motor assembly. See
Replace Procedure.
Motor Does
Not Run
Repair or replace defective
jumper wire or connections.
Is this a Model 950.
Yes
*Manually close the forward
contactor. Is there 230 VAC on
terminals 3 to 5, 5 to 13, & 13 to 3
on the forward contactor?
Yes
No
Check connections at the wire
nut where the three motor
wires are joined.
Repair or replace
defective connection.
Bad
Connection
Good Connection
If this is a single phase unit try
replacing the capicator assy.,
See Replace Procedure.
After verifying the integrity of
the motor connections at the
contactor. Replace defective
motor assembly. See
Replace Procedure.
Motor Does
Not Run
Direct Drive
Manually closing the contactor to check voltage may cause the
wheel to spin at high speeds.To avoid this from happening dis-
connect the wires going from the contactor to the motor.
CAUTION