The wheel balancer provides step by step on-screen
instructions for MACHINE SELF-CALIBRATION and
SPECIAL ADJUSTMENTS. Choose MACHINE SELF-
CALIBRATION when on numerous wheels a one-spin
balance is not achievable. Choose SPECIAL ADJUST-
MENTS when components are added or replaced that
may effect machine dimension measurements.
Machine Self-calibration
Important:
Prior to performing the machine self-cali-
bration, refer to the functional check for calibration on
the back cover.
To access the Machine Self-calibration menu, press
the
key, then select SPECIAL FUNCTIONS
option
and choose MACHINE SELF-CALIBRA-
TION selection
. Follow these instructions on-
screen:
1.
DO NOT CALIBRATE UNTIL YOU HAVE
CHECKED THE FOLLOWING:
• Check Stub Shaft Tightness
• Check for Proper Mounting of Tire/Wheel and for
Speed-Nut Slippage
• Manually Check Wheel Dimensions: Check That
It Matches The Wheel Dimension Icon Within
Approx. 1/4-inch.
• Perform Functional Check Per Procedure
• Check for Proper Phase at Machine Self-Test
Screen
To check for these causes press EXIT or press NEXT
to continue.
2.
Mount a 14", 15", or 16" steel wheel with tire. A
balanced tire/wheel works best. Press NEXT option
to continue.
3.
At this DIM screen manually set the dimensions
carefully before proceeding. See MANUALLY SETTING
WHEEL DIMENSIONS (DIM) on page 23 for further
instructions. Press NEXT option
to continue.
Important:
Dimensions must match the “calibration
wheel”. A dimension cannot be zero.
4.
Lower the hood; then press the
key.
5.
After spin, raise the hood and add test weight to
outside flange at any location: 4.00 oz. (Be sure there
are no weights at same location on the inside rim
flange.)
6.
Lower the hood; then press the
key.
7.
After spin, raise the hood and remove the test
weight on the outside flange and place it directly
across on the inside flange.
Figure 46A - Test Weight Inside Flange Position
8.
Lower the hood; then press the
key.
9.
Raise the hood, rotate the wheel until the test
weight is at 12 o’clock or TDC and hold at this position.
Note:
Step 8 is important, do not skip it.
10.
While holding at the TDC position, press NEXT
option .
Figure 46B - Test Weight Inside Flange Position
11.
Calibration Accepted, press NEXT to EXIT
Machine Self-calibration.
1
START
START
START
1
1
6