Operating Manual 

MULTIROPE 

Summary of Contents for MultiRope Series

Page 1: ...Operating Manual MULTIROPE ...

Page 2: ...ustrial property rights and does not release you from your own obligation to carry out appropriate testing of the products regarding their suitability for the intended application Product descriptions do not contain statements about liability for possible damages However should the case occur liability will be limited to the value of the goods supplied and utilized We are welcoming suggestions and...

Page 3: ...n 6 4 How to Access a Parameter 6 5 How to Adjust a Parameter 7 6 Scheme of Menu 8 9 7 How to Calibrate the Load Measuring 9 10 8 Alarm Limits 10 11 9 How to Adjust the Display 11 10 a CANopen Parameters optionally 12 10 b Electric Characteristics 13 11 Installation des Multirope 14 12 Operation Instructions in Brief 15 ...

Page 4: ...breviation Description Red RD Supply voltage 24 V DC Blue BU Ground White WH Hold input Brown BN Hold input Green GN NO contact Yellow YE NC contact Grey GY COM contact Pink PK NO contact Black BK NC contact Violet VT COM contact Grey Pink GY PK NO contact Red Blau RD BU NC contact White Green WH GN COM contact ...

Page 5: ...v 2 1 09 2016 5 1 Connection Diagram CANopen Wire configuration CANopen Color Colour Abbreviation Description White WH Supply voltage 24 V DC Brown BN Ground Pink PK Hold input Blue BU Hold input Green GN Can H Yellow YE CAN L Grey GY CAN Gnd ...

Page 6: ...ompensation chain Slack Rope Alarm There is a possibility to create negative switching thresholds by setting the first digit to minus Slack rope situations can be detected because the measured weight is below the weight of the car 4 How to Access a Parameter The unit is provided with a menu offering access to the adjustable parameters This key is pressed to browse through the menu items After sele...

Page 7: ...one to be adjusted is displayed 2 Press button to select this parameter 3 Press button to navigate to the value desired for the currently flashing digit Press button to change to the next digit 4 After setting the last digit press button again After that the whole figure will be flashing 5 Press button once more to apply the adjusted parameter ...

Page 8: ...09 2016 8 6 Scheme of Menu current total load 4 digits in the menu item selected calibrating of Multirope cali zero point adjustment tara state changing thresholds of alarm relays alar weight unit unit version number Program Version CANopen CANopen ...

Page 9: ...you will have adjusted the last digit the whole figure will be flashing ii Apply it by pressing After that a countdown will be running from to At the current weight of the car will be measured It goes without saying that at that moment there must not be anything in the cabin or on the car roof that does not belong there under normal operation conditions tools and that there must not stay any perso...

Page 10: ...nging the state of the alarm relay the corresponding status LED will be luminating Standard Model CANopen Model AL 1 freely programmable load Changes its state if the load limit adjusted by parameter is exceeded AL 2 freely programmable load Changes its state if the load limit adjusted by parameter is exceeded AL 3 freely programmable load Changes its state if the load limit adjusted by parameter ...

Page 11: ...l be flashing 5 Press once more to apply the parameter 6 You can quit this menu item at any time by pressing Attention Unless you changed the standard setting of menu item the alarm limits are to be adjusted in terms of percentage i e 100 for full load and 105 for overload 9 How to Adjust the Display Menu item offers two options Weights and alarm limits will be displayed according to the option yo...

Page 12: ...t the desired time interval between two heartbeats may be set in milliseconds Return to submenu The COB ID of the PDO in decimal notation may be adjusted in this menu The default value of 392 0x188h should not be changed under normal circumstances At this point the inhibit time i e the minimum time which has to elapse between two PDOs can be set in tenths of a millisecond steps At this point the e...

Page 13: ...t 12 V DC Fuse 1 A mT HOLD Input 12V 230 V AC DC Relay outputs 3 Relay outputs max switching voltage 250 V AC 220 V DC max starting current 2 A max continuous load current 30 V DC 1 A 125 V AC 0 3 A max switching capacity resistive load 62 VA max switching capacity inductive load 62 VA min switching load DC 10 mV DC 0 01 mA Galvanically isolated no ...

Page 14: ...a must show no signs of previous mechanical effects such as other rope sensors multiple installations etc A distance of at least 10 cm of free rope must be maintained between the rope sockets and load sensor 2 Fitting the sensor in the rope Remove the clamping brace if this has not already been done Distribute the 4 retaining bolts as evenly as possible on the heel of the clamping brace so that th...

Page 15: ...lay an arbitrary load that you will load into the cabin Unless you changed the preset menu item you will have to enter the load in terms of percentage i e 100 if you load the nominal load or 75 if you load of the nominal load for example After setting the last digit the whole figure will be flashing until you confirm it by pressing After that a countdown will be running from to At the current weig...

Page 16: ... Copyright 2016 by Henning GmbH Co KG Rev 2 1 09 2016 16 ...