11. Multirope Installation
1.)
Selection of the appropriate installation area
The area where the Multirope is fitted in the rope must meet the following
requirements:
- The sensor may not mechanically touch other components during the entire
ride of the lift.
- In the area where the sensor is installed the ropes must run straight and show
no signs of defects.
- The installation area must show no signs of previous mechanical effects such
as other rope sensors, multiple installations etc.
- A distance of at least 10 cm of free rope must be maintained between the rope
sockets and load sensor.
2.) Fitting the sensor in the rope
- Remove the clamping brace if this has not already been
done. Distribute the 4 retaining bolts as evenly as possible
on the heel of the clamping brace so that they do not affect
the vertical rope course.
3.) Closing the rope clamp
Introduce the clamping brace over the 4 aligned bolts of
the heel. Alternately tighten up the 4 nuts until the rope
sits close against the heel of the clamping brace.