background image

           Model BCF-24/65/110, BCM-110

2-12.   FUSE AND FUSE

If the unit has no power, the fuse may be blown.  To access the

           HOLDER

fuse:

1. Remove the electrical power to the unit.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.

2. Remove the two screws securing the front panel and pull

down the panel.

3. Unscrew the fuse cap and pull the 10 amp fuse from the

holder.

To check and replace the fuse holder:

1. Remove the two screws securing the front panel and pull

down the panel.

2. Remove the two bolts securing the control box and pull the

control box from the unit. (See Control Board Section.)

3. Remove the four screws securing box top and remove the top.

4. Remove the wires from the fuse holder and check for conti-

nuity across the terminals.  The circuit should show closed.

If open, replace fuse holder.

5. Reinstall the control box and front panel, and unit is now

ready for use.

2-13.   CONDENSATION

1. Remove electrical power to unit and allow evaporator to cool.

           EVAPORATOR

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.

Also, if evaporator is functional, it will be very hot!  Allow
evaporator to cool before removing, or burns could result.

2-6

        603

Fuse Holder

Summary of Contents for BCF Series

Page 1: ...EXPANSION VALVE Any removal or adjustments to these parts must be handled by a SIGHT GLASS AND certifiedrefrigerationexpert CONDENSER FAN 2 4 DISPLAY BOARD AND 1 Remove the electrical power to the un...

Page 2: ...front panel and lower the panel 3 Remove the two bolts under unit securing the control box 4 Pulltheboxfromthefrontoftheunit 5 Remove the four screws securing the control box top and pull the top from...

Page 3: ...top from the box 6 Label and remove the wires to the buzzer 7 Remove the two screws securing the buzzer to the bracket and remove the buzzer from the bracket 8 Install new buzzer in reverse order 2 7...

Page 4: ...ent fromtheunit 5 Install new heater in reverse order and press the plastic tabs in place to secure the decorator covers tabs included with new heater 2 9 EVAPORATOR FAN 1 Remove the electrical power...

Page 5: ...o the PC board and remove the wires from the board 6 Pull the probe wire through the wiring harness 7 Install new probe in reverse order 2 11 FRIGIPROBE 1 Remove the electrical power to the unit To av...

Page 6: ...emove the two bolts securing the control box and pull the control box from the unit See Control Board Section 3 Remove the four screws securing box top and remove the top 4 Remove the wires from the f...

Page 7: ...r 4 Pull up on the bottom of the evaporator to disengage the evaporator from the bracket The evaporator is snapped into place No hardware is securing it 5 Replace evaporator in reverse order 2 14 DOOR...

Page 8: ...lay to the capacitor 6 Remove the capacitor from the unit from the front 7 Install new capacitor in reverse order 2 16 START CAPACITORAND 1 Remove the electrical power to the unit START RELAY To avoid...

Page 9: ...er Freezer does require care and proper mainte nance The table below provides a summary of sched uledmaintenance Procedure Frequency Clean all surfaces with a soft cloth soap and water Daily do not us...

Page 10: ...Model BCF 24 65 110 BCM 110 Wiring Diagrams BCF BCM 110 2 10 603...

Page 11: ...Model BCF 24 65 110 BCM 110 Wiring Diagram BCF 24 65 Refrigeration Diagram BCF 24 65 603 2 11...

Page 12: ...Model BCF 24 65 110 BCM 110 Refrigeration Diagram BCF BCM 110 UL Refrigeration Diagram BCF BCM 110 Int l 2 12 603...

Page 13: ...Model BCF 24 65 110 BCM 110 Electrical Refrigeration Diagram 603 2 13...

Page 14: ...POWER SUPPLY OUTPUT TO FAN S AND FRONT FRAME HEATER ANTI FOGGING 10 11 POWER SUPPLY OUTPUT TO COMPRESSOR UNIT 12 13 12VDC OUTPUT TO ALARM BUZZER NOT USED 14 DISPLAY INPUTS 15 19 FRIGIPROBE INPUTS BLAC...